Skip to main content
Siemens 5SQ2170-2YA32 — 1-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2170-2YA32 MCB, 1-pole C-curve 32 A 3 kA

MPN5SQ2170-2YA32

Siemens SENTRON 5SQ miniature circuit breaker, 1-pole, C-curve, 32 A rated current, 3 kA breaking capacity per EN 60898, 240 V AC, IP20, 55 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2170-2YA32 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
5SQ2170-2YA32 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Energy limitation class3
Overvoltage category3
5SQ2170-2YA32 — Mounting & Connection
ParameterValue
Installation depth55 mm
Modular width units1
5SQ2170-2YA32 — Environmental
ParameterValue
IP protection classIP20
Pollution degree3
5SQ2170-2YA32 — Other specifications
ParameterValue
Type of voltageAC/DC
Design of the productMiniature circuit breaker 5SQ
Number of poles (Note)1P
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Operational current (at AC)32 A
Product function (Neutral conductor switching)No

Product details

The Siemens SENTRON 5SQ2170-2YA32 is a 1-pole miniature circuit breaker (MCB) with a C-curve tripping characteristic, rated 32 A at 240 V AC and 50 Hz. It is designed for branch-circuit overcurrent and short-circuit protection in final distribution boards, lighting circuits, and general-purpose loads where moderate inrush currents (e.g., small motors, transformers, fluorescent ballasts) are expected. The C-curve means it trips magnetically at 5–10 times rated current — a good fit for mixed resistive-inductive loads that don't need the higher inrush headroom of a D-curve.

Rated breaking capacity is 3 kA per EN 60898 — the standard for household and similar installations. That's the maximum prospective short-circuit current the MCB can safely interrupt at its rated voltage. In a commercial or light industrial panel fed by a transformer with a low-impedance path, fault levels can exceed 3 kA; if your available fault current is higher, this breaker is not the right choice. For comparison, the 3-pole sibling 5SQ2370-2YA04 shares the same 3 kA rating but at 400 V and 4 A — same series, same fault-handling capability, different pole/current configuration.

Single modular width unit (1 MW) with an installation depth of 55 mm — fits standard DIN-rail enclosures used across the SENTRON 5SQ series.

Frequently asked questions

What is the breaking capacity of 5SQ2170-2YA32?

It is rated 3 kA per EN 60898 at 240 V AC — the standard for household and similar installations, sufficient for most final sub-circuits but not for high-fault panels above that level.

Will 5SQ2170-2YA32 drop into a panel specified around 5SQ2370-2YA04 without rewiring?

No — the 5SQ2370-2YA04 is a 3-pole, 4 A, 400 V MCB. The 5SQ2170-2YA32 is 1-pole, 32 A, 240 V. They share the same 55 mm depth and DIN-rail footprint, but the pole count, voltage, and current ratings differ, so a direct swap without rewiring is not possible.

Where can I buy 5SQ2170-2YA32?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ to receive a firm offer.

MPN
5SQ2170-2YA32