Siemens SENTRON 5SQ2260-0KA13 MCB, 2P, B Curve, 13 A, 400 V

MPN5SQ2260-0KA13

Siemens SENTRON 5SQ2260-0KA13, miniature circuit breaker, 2-pole, B characteristic, 13 A rated at 400 V AC, 3 kA breaking capacity per EN 60898, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2260-0KA13 — Identification
ParameterValue
Brand nameSENTRON
5SQ2260-0KA13 — Electrical
ParameterValue
Number of poles2
5SQ2260-0KA13 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage category3
5SQ2260-0KA13 — Mechanical
ParameterValue
Installation depth55 mm
Protection degree (IP)IP20
5SQ2260-0KA13 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)13 A
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The Siemens SENTRON 5SQ2260-0KA13 is a 2-pole miniature circuit breaker (MCB) from the 5SQ series, rated at 13 A with a B tripping characteristic. It is designed for 400 V AC, 50 Hz systems and carries a 3 kA breaking capacity per EN 60898 — adequate for branch-circuit protection in residential and light commercial distribution boards where the prospective short-circuit current stays under that threshold.

The B-curve trips between 3 and 5 times rated current (39–65 A magnetic release), making it the standard choice for resistive and general-purpose loads — lighting, socket outlets, control transformers — where inrush is modest. The 3 kA breaking capacity (Icn) per EN 60898 certifies it for use where the fault level at the installation point does not exceed 3 kA; above that, selectivity with an upstream device or a higher-rated MCB (e.g., the SENTRON 3VA series) is required. The neutral conductor is switched, so the 2-pole device opens both phase and neutral — required in some regional wiring rules for final circuits and for isolating the neutral during maintenance.

Deployment context

Occupies 2 width units (approx. 36 mm) on a DIN rail, with a 55 mm installation depth — fits standard distribution boards and sub-distribution panels.

Frequently asked questions

Where can I buy 5SQ2260-0KA13 and how do I get a price?

The 5SQ2260-0KA13 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 5SQ2260-0KA13's listed number of poles?

The 5SQ2260-0KA13 is a 2-pole (2P) device, switching both phase and neutral.

What is 5SQ2260-0KA13's listed type of voltage?

The 5SQ2260-0KA13 is rated for AC/DC operation, with a rated supply voltage of 400 V AC at 50 Hz.

Will 5SQ2260-0KA13 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

No — the 3VA1110-5ED36-0AC0 is a 3-pole molded-case circuit breaker (MCCB) with a 100 A frame, box terminals, and a 70 mm depth, while the 5SQ2260-0KA13 is a 2-pole MCB on a 55 mm DIN-rail footprint. They are not form-fit interchangeable; rewiring and a different DIN-rail position would be required.

What compliance documentation does Siemens provide for 5SQ2260-0KA13?

The breaker is designed per EN 60898 and carries overvoltage category 3 and energy limiting class 3 ratings. Siemens typically provides a declaration of conformity and CE marking for the SENTRON series; specific documentation (RoHS, REACH, UL) should be requested at quote time.