Siemens 5SQ2270-0KA08 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2270-0KA08 MCB, 2-Pole, C-Curve, 8 A, 400

MPN5SQ2270-0KA08

Siemens SENTRON 5SQ series, miniature circuit breaker, 5SQ2270-0KA08, 2-pole, C-curve, 8 A, 400 V AC, 3 kA breaking capacity, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2270-0KA08 — Identification
ParameterValue
Brand nameSENTRON
5SQ2270-0KA08 — Electrical
ParameterValue
Number of poles2
5SQ2270-0KA08 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SQ2270-0KA08 — Mechanical
ParameterValue
Installation depth55 mm
Protection degree (IP)IP20
5SQ2270-0KA08 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)8 A
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

It is designed for branch-circuit overcurrent and short-circuit protection in final distribution panels, with a breaking capacity of 3 kA per EN 60898. The 2-pole configuration with neutral switching means it disconnects both phase and neutral, which is standard for single-phase final circuits in many European and IEC-based installations.

Fit and installation

The IP20 finger-safe terminals are standard for enclosed distribution boards — no special sealing needed inside a panel. Energy limiting class 3 indicates it restricts let-through energy well, reducing stress on downstream equipment during a fault.

The MCB is designed to EN 60898, the harmonized European standard for household and similar installations. The SENTRON brand carries the usual Siemens compliance documentation — RoHS, REACH, and CE marking are standard for this series. For a maintenance-spares purchaser or quality-doc controller, the nameplate data and declaration of conformity are available from Siemens directly or through the supply chain.

Frequently asked questions

What is the breaking capacity of 5SQ2270-0KA08?

The breaking capacity is 3 kA per EN 60898. This is sufficient for most residential and light commercial final distribution boards where the prospective short-circuit current is under that threshold.

Where can I buy 5SQ2270-0KA08?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

Will 5SQ2270-0KA08 drop into a panel specified around the 5SQ2270-2YA04 without rewiring?

Both are 2-pole, 400 V, C-curve SENTRON MCBs with the same DIN-rail footprint and 55 mm depth. The difference is the current rating: 8 A on this part versus 4 A on the 2YA04. If the panel wiring and load are sized for 8 A, it drops in physically without rewiring — but the circuit protection rating must match the downstream cable and load.

MPN