Siemens 5SQ2270-0KA40 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2270-0KA40 Circuit Breaker, 2-Pole, C, 40

MPN5SQ2270-0KA40

Siemens SENTRON 5SQ series, 5SQ2270-0KA40, 2-pole miniature circuit breaker, 40 A rated current, C tripping characteristic, 3 kA breaking capacity per EN 60898, 400 V AC, IP20.

$91.54Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2270-0KA40 — Identification
ParameterValue
Brand nameSENTRON
5SQ2270-0KA40 — Electrical
ParameterValue
Number of poles2
5SQ2270-0KA40 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SQ2270-0KA40 — Mechanical
ParameterValue
Installation depth55 mm
Protection degree (IP)IP20
5SQ2270-0KA40 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)40 A
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The Siemens SENTRON 5SQ2270-0KA40 is a 2-pole miniature circuit breaker rated for 40 A at 400 V AC, with a C tripping characteristic and a 3 kA breaking capacity per EN 60898. It also handles DC circuits (type of voltage AC/DC). This is the part for a 40 A branch circuit needing a C-curve — the magnetic trip holds through moderate inrush (motor starts, capacitor banks, transformer energization) and clears on sustained overload.

Snaps onto standard DIN rail. Occupies 2 width units (about 36 mm) and has an installation depth of 55 mm — shallow enough for most flush-mount enclosures. IP20 rated, so it belongs inside a closed distribution board or panel, not in a wet or dusty location. Neutral conductor switching is integrated (product function / neutral conductor switching = Yes), which simplifies wiring in 2P applications where you want to isolate both phase and neutral.

Frequently asked questions

Where can I buy 5SQ2270-0KA40?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SQ2270-0KA40?

The breaking capacity is 3 kA according to EN 60898 at 400 V AC.

What does the C tripping characteristic mean on this breaker?

The C-curve means the magnetic trip activates at 5 to 10 times the rated current (200 to 400 A for this 40 A unit). It is suited for circuits with moderate inrush, such as motor starters or small transformers, where a B-curve would nuisance-trip.

Will 5SQ2270-0KA40 drop into a panel specified around 5SU9304-1KK32?

No — the 5SU9304-1KK32 is an RCBO (RCD + MCB) with 1P+N design, 32 A, and a 10 kA breaking capacity. The 5SQ2270-0KA40 is a plain MCB, 2-pole, 40 A, 3 kA. They are not drop-in interchangeable; the panel wiring and fault-current rating differ.