Skip to main content
Siemens 5SQ2270-2YA50 — 2-Pole MCB (DIN Rail)

SENTRON 5SQ2270-2YA50 Miniature Circuit Breaker, 2-Pole, C 5

MPN5SQ2270-2YA50

SENTRON 5SQ2270-2YA50 miniature circuit breaker, 2-pole, C-curve, 50 A, 400 V AC, 3 kA breaking capacity per EN 60898, IP20, 55 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2270-2YA50 — Identification
ParameterValue
Brand nameSENTRON
5SQ2270-2YA50 — Electrical
ParameterValue
Number of poles2
5SQ2270-2YA50 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SQ2270-2YA50 — Mechanical
ParameterValue
Installation depth55 mm
Protection degree (IP)IP20
5SQ2270-2YA50 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)50 A
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The SENTRON 5SQ2270-2YA50 is a 2-pole miniature circuit breaker (MCB) rated 50 A at 400 V AC with a C tripping characteristic. The 3 kA breaking capacity per EN 60898 is the maximum fault current it can safely interrupt at 400 V; for most residential, commercial, and light industrial distribution boards this is sufficient, but verify against your panel's prospective short-circuit current (PSCC). The 55 mm installation depth fits standard distribution board cutouts; the 2 width units (36 mm per DIN 43880) occupy two module spaces on the DIN rail.

Deployment context

Snap-on DIN rail mounting, IP20 finger-safe terminals — intended for enclosed distribution boards or control panels where the breaker is not exposed to washdown or dust. The AC/DC voltage type means the same unit can be used on DC circuits up to 48 V or 60 V (derate current per manufacturer curve), though the primary rating is 400 V AC at 50 Hz.

Frequently asked questions

What is the breaking capacity of 5SQ2270-2YA50?

3 kA per EN 60898 at 400 V AC. This is the maximum fault current it can safely interrupt; verify against your panel's prospective short-circuit current.

Where can I buy 5SQ2270-2YA50?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SQ2270-2YA50 drop into a panel specified for 5SQ2570-2YA04?

Yes — both are 2-pole, same 55 mm depth, same 2 width units, same DIN-rail footprint. The only difference is the current rating: 50 A vs 4 A. No rewiring or panel modification is needed.

MPN
5SQ2270-2YA50