Siemens 5SQ2360-0KA10 — Miniature Circuit Breakers (MCB)

Siemens SENTRON 5SQ2360-0KA10 MCB, 3-pole, B-curve, 10 A, 3

MPN5SQ2360-0KA10

Siemens SENTRON 5SQ series, 5SQ2360-0KA10 miniature circuit breaker, 3-pole, B-curve, 10 A, 3 kA breaking capacity per EN 60898, 400 V AC/DC, IP20, 3 width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2360-0KA10 — Ratings
ParameterValue
Overvoltage category3
5SQ2360-0KA10 — Other specifications
ParameterValue
Poles3
Type of voltageAC/DC
Installation depth55 mm
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P
Circuit-breaker (Design)5SQ
Current (at AC)10 A
Tripping characteristic classB
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

The Siemens SENTRON 5SQ2360-0KA10 is a 3-pole miniature circuit breaker (MCB) with a B-curve tripping characteristic, rated at 10 A and 400 V AC/DC. The B-curve means it trips between 3 and 5 times rated current (30–50 A), which suits resistive and general-purpose loads where inrush is modest — lighting, socket outlets, small control transformers. For motor circuits or capacitive loads with higher inrush, a C-curve sibling would be the call.

Occupies 3 width units (roughly 54 mm) on a standard DIN rail, with an installation depth of 55 mm. The AC/DC voltage rating means it can switch DC control circuits as well as AC power, though the 3 kA breaking capacity is rated per EN 60898 for AC; DC derating applies per the manufacturer's data.

Frequently asked questions

What is the number of poles on 5SQ2360-0KA10?

It is a 3-pole device, switching all three phases simultaneously.

What type of voltage does 5SQ2360-0KA10 support?

Rated for both AC and DC supply voltage, at 400 V AC and compatible DC levels.

Will 5SQ2360-0KA10 drop into a panel specified around 5SQ2360-0KA16 without rewiring?

Yes — both share the same 3-pole footprint, 3 width units, 55 mm depth, and B-curve. The only difference is the current rating: 10 A vs 16 A. So the panel wiring and busbar fit are identical; just verify the load current matches the 10 A rating.

Who supplies 5SQ2360-0KA10 and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent industrial distribution channels. Availability and current pricing are confirmed at the time of quote — submit an RFQ for volume pricing and lead time.

MPN