SENTRON 5SQ2360-0KA16 MCB, 3-Pole, B Curve, 16 A, 3 kA

MPN5SQ2360-0KA16

Siemens SENTRON 5SQ2360-0KA16, 3-pole miniature circuit breaker, B tripping characteristic, 16 A rated current, 3 kA breaking capacity, 400 V AC, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2360-0KA16 — Ratings
ParameterValue
Overvoltage category3
5SQ2360-0KA16 — Other specifications
ParameterValue
Poles3
Type of voltageAC/DC
Installation depth55 mm
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P
Circuit-breaker (Design)5SQ
Current (at AC)16 A
Tripping characteristic classB
Acc. to EN 60898 / rated value3 kA
Acc. to IEC 60947-2 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

The Siemens SENTRON 5SQ2360-0KA16 is a 3-pole miniature circuit breaker (MCB) with a B tripping characteristic, rated 16 A at 400 V AC, 50 Hz. That 3 kA rating is the same across both standards, which simplifies coordination in a mixed-certification panel.

Three width units (each 18 mm) on a standard DIN rail — 54 mm total rail space. Installation depth is 55 mm, so it sits flush in a typical distribution board without crowding the gland plate. IP20 rated, meaning finger-safe terminals but no washdown tolerance; keep it inside a closed enclosure. No neutral switching (the neutral bar runs through separately), which is standard for 3-pole breakers in a 3-phase system where the neutral is solid.

Frequently asked questions

Where can I buy 5SQ2360-0KA16 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 5SQ2360-0KA16's listed number of poles?

It is a 3-pole breaker (3P), with no neutral switching. Three width units on the DIN rail, each 18 mm, for a total of 54 mm.

Will 5SQ2360-0KA16 drop into a panel that was specified around 5SQ2370-2YA04 without rewiring?

Physically yes — same 3-pole DIN-rail footprint, same 55 mm depth, same 3 width units. But the electrical protection is different: B-curve 16 A vs C-curve 4 A. The wiring may fit, but the protection coordination changes. Verify the branch load and upstream device before swapping.