Skip to main content
Siemens 5SQ2360-0KA32 — Miniature Circuit Breakers (MCB)

SENTRON 5SQ2360-0KA32 Circuit Breaker, 3-Pole, B, 32A, 3kA

MPN5SQ2360-0KA32

SENTRON 5SQ2360-0KA32, 3-pole circuit breaker, B characteristic, 32 A, 3 kA per EN 60898, 400 V AC, 50 Hz, IP20, 55 mm installation depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2360-0KA32 — Ratings
ParameterValue
Overvoltage category3
5SQ2360-0KA32 — Other specifications
ParameterValue
Poles3
Type of voltageAC/DC
Installation depth55 mm
Degree of pollution3
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P
Circuit-breaker (Design)5SQ
Tripping characteristic classB
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Operating current (at AC)32 A
Product function (neutral conductor switching)No

Product details

The SENTRON 5SQ2360-0KA32 is a 3-pole miniature circuit breaker (MCB) with a B tripping characteristic, rated 32 A at 400 V AC, 50 Hz, and a breaking capacity of 3 kA per EN 60898. The B-curve means it trips between 3 and 5 times rated current — suited for resistive or general-purpose loads where inrush is modest, not for motor circuits with high starting currents. The 3 kA breaking capacity is the maximum fault current it can safely interrupt at 400 V per the standard; verify that the prospective short-circuit current at the installation point does not exceed this value.

Panel fit and integration

The 5SQ2360-0KA32 occupies 3 width units (roughly 54 mm) on a DIN rail, with an installation depth of 55 mm. The IP20 finger-safe enclosure is standard for panel mounting — no washdown rating, so keep it inside the cabinet. Pollution degree 3 and overvoltage category 3 mean it's rated for industrial environments where conductive pollution or transient overvoltages are expected. The 3-pole design does not switch the neutral conductor; confirm your distribution scheme accounts for that.

Frequently asked questions

What are the key ratings of the 5SQ2360-0KA32?

It is a 3-pole, B-curve MCB rated 32 A at 400 V AC, 50 Hz, with a 3 kA breaking capacity per EN 60898. The installation depth is 55 mm and it occupies 3 width units on a DIN rail.

Where can I buy the 5SQ2360-0KA32?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote.

Will the 5SQ2360-0KA32 drop into a panel specified for the 5SQ2360-0KA16?

Yes, both share the same 3-pole DIN-rail footprint, 55 mm depth, and 3 width units. The only difference is the current rating — 32 A versus 16 A — so the panel wiring and upstream protection must be sized for 32 A.

MPN