Siemens 5SQ2370-0KA01 — Miniature Circuit Breakers (MCB)

SENTRON 5SQ2370-0KA01 MCB, 3-pole C 1A 400V AC 3kA

MPN5SQ2370-0KA01

SENTRON 5SQ2370-0KA01, miniature circuit breaker, 3-pole, C-curve, 1 A, 400 V AC, 3 kA breaking capacity per EN 60898, IP20, 55 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2370-0KA01 — Ratings
ParameterValue
Overvoltage category3
5SQ2370-0KA01 — Other specifications
ParameterValue
Poles3
Type of voltageAC/DC
Installation depth55 mm
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P
Circuit-breaker (Design)5SQ
Current (at AC)1 A
Tripping characteristic classC
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

SENTRON 5SQ2370-0KA01 — 3-pole C-curve MCB, 1 A, 400 V AC

The SENTRON 5SQ2370-0KA01 is a 3-pole miniature circuit breaker with C-curve tripping characteristic, rated 1 A at 400 V AC and a breaking capacity of 3 kA per EN 60898. The C-curve (energy limiting class 3) means it trips between 5 and 10 times rated current — suited for protecting general-purpose circuits with moderate inrush, like lighting banks or small transformer loads. The 3 kA SCCR at 400 V AC is the maximum fault current it can safely interrupt under EN 60898; verify it coordinates with the upstream protective device in your panel. EN 60898 certifies its performance for household and similar installations.

Panel integration

The 5SQ2370-0KA01 occupies 3 width units on a DIN rail, with an installation depth of 55 mm. IP20 finger-safe terminals suit enclosed panel mounting.

Frequently asked questions

How do I get current pricing and availability for 5SQ2370-0KA01?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time; the part is sourced to order through independent distribution.

What is 5SQ2370-0KA01's listed number of poles?

It is a 3-pole (3P) device, meaning it switches and protects all three phases simultaneously.

What is 5SQ2370-0KA01's listed type of voltage?

It is rated for AC/DC voltage, though the breaking capacity (3 kA) is specified under AC conditions per EN 60898.

Will 5SQ2370-0KA01 drop into a panel specified around 5SQ2370-2YA01 without rewiring?

Yes — both are 3-pole, C-curve, 1 A, 400 V AC, 3 kA, same footprint (3 width units, 55 mm depth). The 5SQ2370-2YA01 is a functional equivalent; no rewiring needed.

What compliance documentation does this brand provide for 5SQ2370-0KA01?

As a SENTRON device, it carries EN 60898 certification for breaking capacity. Specific RoHS/REACH/UL declarations are available from the manufacturer upon request; no such documents are included in this listing.

MPN
5SQ2370-0KA01