SENTRON 5SQ2370-0KA02 MCB, 3-pole C-curve 2 A, 3 kA

MPN5SQ2370-0KA02

SENTRON 5SQ2370-0KA02, 3-pole miniature circuit breaker, C tripping characteristic, 2 A rated current, 3 kA breaking capacity per EN 60898 at 400 V AC, 50 Hz, IP20, 55 mm installation depth.

$53.02Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2370-0KA02 — Ratings
ParameterValue
Overvoltage category3
5SQ2370-0KA02 — Other specifications
ParameterValue
Poles3
Type of voltageAC/DC
Installation depth55 mm
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P
Circuit-breaker (Design)5SQ
Current (at AC)2 A
Tripping characteristic classC
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

The SENTRON 5SQ2370-0KA02 is a 3-pole miniature circuit breaker (MCB) from the 5SQ series, rated at 2 A with a C tripping characteristic. It is designed for 400 V AC, 50 Hz systems and carries a 3 kA breaking capacity per EN 60898 — the standard for household and similar installations, certifying it for branch-circuit protection in residential and light commercial distribution boards.

The 3-pole format (3P, no neutral switching) occupies 3 width units on a DIN rail, with a 55 mm installation depth — standard for compact consumer-unit or sub-distribution enclosures. IP20 finger-safe terminals suit enclosed panel mounting; the part is not rated for exposed or washdown environments.

The C-curve trips at 5–10× rated current (10–20 A for this 2 A unit), making it suitable for moderate inrush loads such as small motor starters, lighting banks, and transformer primaries. Overvoltage category 3 and energy limiting class 3 are consistent with fixed-installation mains protection.

Frequently asked questions

Where can I buy 5SQ2370-0KA02 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.

What is 5SQ2370-0KA02's listed number of poles?

The 5SQ2370-0KA02 is a 3-pole device (3P), with no neutral conductor switching.

What is 5SQ2370-0KA02's listed type of voltage?

The type of voltage is AC/DC — the breaker is rated for AC circuits at 400 V, 50 Hz.

Will 5SQ2370-0KA02 drop into a panel specified around 5SQ2370-2YA04 without rewiring?

Yes — both are 3-pole, 55 mm deep, IP20, C-curve SENTRON 5SQ breakers with the same physical footprint and DIN-rail mounting. The only difference is the current rating: 2 A on the 5SQ2370-0KA02 versus 4 A on the 5SQ2370-2YA04. The breaker will fit the same busbar and enclosure without rewiring, but the load must not exceed 2 A.