Skip to main content
Siemens 5SQ2370-0KA32 — Miniature Circuit Breakers (MCB)

SENTRON 5SQ2370-0KA32 MCB, 3-pole, C-curve, 32 A, 3 kA

MPN5SQ2370-0KA32

SENTRON 5SQ2370-0KA32, miniature circuit breaker, 3-pole, C-curve, 32 A, 3 kA breaking capacity per EN 60898, 400 V AC, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2370-0KA32 — Ratings
ParameterValue
Overvoltage category3
5SQ2370-0KA32 — Other specifications
ParameterValue
Poles3
Type of voltageAC/DC
Installation depth55 mm
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P
Circuit-breaker (Design)5SQ
Current (at AC)32 A
Tripping characteristic classC
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

Integrator note — 5SQ2370-0KA32

The SENTRON 5SQ2370-0KA32 is a 3-pole miniature circuit breaker (MCB) with a C tripping characteristic, rated 32 A at 400 V AC and a breaking capacity of 3 kA per EN 60898. The 3 kA SCCR at 400 V is the standard residential and light-commercial fault level; for higher fault currents you'd step up to an SENTRON 5SL or 5SY series with 6 kA or 10 kA ratings. EN 60898 certifies it for overcurrent protection in household and similar installations — not for industrial motor-starting duty under IEC 60947-2, which the 5SY series covers.

Installation depth is 55 mm — fits standard distribution boards with cover clearance. Overvoltage category 3 (4 kV impulse withstand) suits fixed-installation mains connection. Energy limiting class 3 means it reduces let-through energy under fault, aiding downstream device protection. No neutral switching (3-pole only; neutral bar required separately).

Frequently asked questions

What is the breaking capacity of 5SQ2370-0KA32?

3 kA at 400 V AC, rated per EN 60898. That is the standard fault-interruption level for household and light-commercial final circuits.

Where can I buy 5SQ2370-0KA32?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SQ2370-0KA32 drop into a panel specified for 5SQ2370-2YA04 without rewiring?

Yes — both are 3-pole SENTRON T55 MCBs with the same 55 mm depth, IP20, and DIN-rail footprint. The only difference is the current rating: 32 A versus 4 A (5SQ2370-2YA04). No rewiring needed if the circuit is rated for 32 A.

MPN
5SQ2370-0KA32