Siemens 5SQ2370-2YA02 — Miniature Circuit Breakers (MCB)

Siemens SENTRON 5SQ2370-2YA02 MCB, 3-pole, C-curve, 2 A, 3 k

MPN5SQ2370-2YA02

Siemens SENTRON 5SQ2370-2YA02 miniature circuit breaker, 3-pole, C characteristic, 2 A, 3 kA breaking capacity at 400 V AC, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2370-2YA02 — Ratings
ParameterValue
Overvoltage category3
5SQ2370-2YA02 — Other specifications
ParameterValue
Poles3
Type of voltageAC/DC
Installation depth55 mm
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P
Circuit-breaker (Design)5SQ
Current (at AC)2 A
Tripping characteristic classC
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)No

Product details

What it is and what it does

The Siemens SENTRON 5SQ2370-2YA02 is a 3-pole miniature circuit breaker (MCB) with a C tripping characteristic, rated at 2 A at 400 V AC and a 3 kA breaking capacity per EN 60898. The C-curve means it trips at 5 to 10 times rated current — designed for moderate inrush loads like small motors, transformers, or lighting banks where a B-curve would nuisance-trip on startup. The 3 kA breaking capacity at 400 V AC covers most final subcircuits in residential and light commercial distribution boards; if your fault current exceeds that, you need an upstream current-limiting device. Accepts AC or DC supply voltage, occupies 3 width units, installation depth 55 mm, IP20.

Panel fit and integration

Snap-on DIN rail mount, 3 width units, 55 mm installation depth. No neutral conductor switching. Overvoltage category 3 and energy limiting class 3 — suitable for fixed installations downstream of the main distribution board, where transient overvoltages are already limited by upstream SPDs.

Frequently asked questions

Will 5SQ2370-2YA02 drop into a panel specified around 5SQ2370-2YA04 without rewiring?

Yes — both are 3-pole, C-curve, 3 kA, 400 V AC, same physical footprint (3 width units, 55 mm depth). The only difference is the current rating: 2 A vs 4 A. If the circuit load is under 2 A, it's a direct swap; if the original design called for 4 A, the 2 A will trip on the load.

What is 5SQ2370-2YA02's listed number of poles?

3 poles (3P).

What is 5SQ2370-2YA02's listed type of voltage?

AC/DC — it can be used on both AC and DC circuits within its rated parameters.