Siemens 5SQ2370-2YA16 — Miniature Circuit Breakers (MCB)

Siemens 5SQ2370-2YA16 SENTRON MCB, 3-pole, C 16 A, 3 kA

MPN5SQ2370-2YA16

Siemens SENTRON 5SQ2370-2YA16 miniature circuit breaker, 3-pole, C-curve 16 A, 3 kA breaking capacity at 400 V AC per EN 60898, 55 mm installation depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2370-2YA16 — Ratings
ParameterValue
Overvoltage category3

Product details

What it is and what it does

The Siemens SENTRON 5SQ2370-2YA16 is a 3-pole miniature circuit breaker (MCB) with C-curve tripping characteristic, rated 16 A at 400 V AC. It is built to EN 60898 with a 3 kA breaking capacity, making it suitable for branch-circuit protection in commercial and light-industrial panels where the prospective short-circuit current stays under that threshold.

What the ratings mean for fit

The C-curve means the breaker trips at 5 to 10 times rated current — a common choice for motor circuits, transformers, and lighting banks with moderate inrush. At 16 A it protects a 3-phase load drawing roughly 11 kW at 400 V. The 3 kA breaking capacity is the maximum fault current it can safely interrupt per EN 60898; if your panel's available fault current exceeds that, you need a higher-rated MCB or a current-limiting upstream device. Thermal derating is built in: at 40 °C ambient the continuous rating drops to 15.2 A, at 50 °C to 14.4 A, and at 60 °C to 13.6 A (–). If the breaker lives in a hot enclosure (stacked with other heat sources), size the load to the derated value, not the 30 °C nameplate.

Installation and panel fit

It occupies 3 modular width units on a DIN rail, with a shallow 55 mm installation depth — useful for tight enclosures where the standard 70–76 mm depth of many SENTRON MCBs won't clear the gland plate or door. Pollution degree 3 and overvoltage category III mean it's rated for fixed installations in industrial environments where transient overvoltages are expected. IP20 provides finger-safe terminal protection once the busbar and wiring are in place.

Frequently asked questions

What is the breaking capacity of 5SQ2370-2YA16?

It has a 3 kA breaking capacity per EN 60898 at 400 V AC. That is the maximum fault current it can safely clear; verify your panel's prospective short-circuit current stays below this level.

What is the difference between 5SQ2370-2YA16 and the 5SL4363-7?

Both are 3-pole C-curve MCBs, but the 5SL4363-7 carries a 10 kA breaking capacity per EN 60898 and IEC 60947-2 (versus 3 kA on the 5SQ2370-2YA16), and has a 76 mm depth versus 55 mm. The 5SL4363-7 also supports supplementary devices and has 10,000 operating cycles. Choose the 5SQ2370-2YA16 when panel depth is constrained and fault current is under 3 kA; the 5SL4363-7 fits higher-fault applications or where a spare auxiliary contact may be needed later.

Will 5SQ2370-2YA16 drop into a panel specified around 5SL6016-7KL?

Not without rewiring. The 5SL6016-7KL is a 2-pole (1P+N) MCB with neutral switching, occupying 1 modular width and 70 mm depth, rated 230 V AC. The 5SQ2370-2YA16 is a 3-pole breaker (3 modular widths, 55 mm depth) at 400 V AC. The footprint, voltage, and pole configuration differ completely.

Where can I buy 5SQ2370-2YA16?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and ETA.