Skip to main content
Siemens 5SQ2560-0KA20 — 1-Pole MCB (DIN Rail)

SENTRON 5SQ2560-0KA20 MCB, 2-pole 1P+N, B-curve, 20 A, 3 kA

MPN5SQ2560-0KA20

SENTRON 5SQ2560-0KA20, miniature circuit breaker, 2-pole 1P+N, B characteristic, 20 A, 3 kA, 240 V AC, 50 Hz, IP20, 55 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2560-0KA20 — Identification
ParameterValue
Brand nameSENTRON
Number of poles2
5SQ2560-0KA20 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2560-0KA20 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2560-0KA20 — Environmental
ParameterValue
IP protection classIP20
5SQ2560-0KA20 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)1P+N
Circuit-breaker (Design)5SQ
Current (at AC)20 A
Acc. to IEC 60947-2 / rated value3 kA
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

It breaks fault currents up to 3 kA per both EN 60898 and IEC 60947-2 at 240 V AC, 50 Hz. That's a good fit for resistive loads like lighting strings, heating elements, or general-purpose socket circuits where inrush is low. For motor or transformer feeders with higher inrush, a C or D curve would be the better call; this one will nuisance-trip on a pump start.

The 5SQ2560-0KA20 occupies 2 width units (about 36 mm) on a DIN rail and installs at 55 mm depth — shallow enough for a 100 mm deep enclosure with room for gland plates and wiring gutters. IP20 finger-safe terminals are standard for enclosed panel gear; no washdown rating here, so it stays inside the cabinet. That saves a terminal slot and keeps the wiring tidy in a single-phase sub-feed.

This part carries a current lifecycle stage from the manufacturer — no phase-out notice on record. That means it's still a standard catalog line, not a last-time-buy scavenger hunt.

Frequently asked questions

What is the 5SQ2560-0KA20 used for?

It's a 2-pole 1P+N miniature circuit breaker rated 20 A with a B tripping characteristic, used for overcurrent and short-circuit protection of lighting, heating, and general-purpose socket circuits in single-phase 240 V AC panels.

MPN
5SQ2560-0KA20