Siemens 5SQ2560-0KA32 — 1-Pole MCB (DIN Rail)

SENTRON 5SQ2560-0KA32 MCB, 2-Pole B 32A, 3kA

MPN5SQ2560-0KA32

SENTRON 5SQ2560-0KA32, 2-pole 1P+N miniature circuit breaker, B-curve, 32 A, 3 kA breaking capacity, 240 V AC, 50 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2560-0KA32 — Identification
ParameterValue
Brand nameSENTRON
Number of poles2
5SQ2560-0KA32 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2560-0KA32 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2560-0KA32 — Environmental
ParameterValue
IP protection classIP20
5SQ2560-0KA32 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)1P+N
Circuit-breaker (Design)5SQ
Current (at AC)32 A
Acc. to IEC 60947-2 / rated value3 kA
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The SENTRON 5SQ2560-0KA32 is a 2-pole miniature circuit breaker (1P+N) with a B tripping characteristic, rated 32 A at 240 V AC, 50 Hz. The 32 A rating covers a typical ring-main or a large lighting radial. That 3 kA SCCR matches the typical prospective fault current at the downstream end of a distribution board; upstream coordination with a higher-rated device is assumed for installations with higher available fault current.

DIN-rail integration and panel fit

The 5SQ2560-0KA32 occupies 2 width units (roughly 36 mm) on a standard 35 mm DIN rail, with an installation depth of 55 mm. IP20 finger-safe terminals are standard for enclosed distribution boards. The 1P+N configuration switches both phase and neutral, with the neutral pole switching but not protecting — the overcurrent trip acts only on the phase pole. This is the common arrangement for single-phase final circuits where the neutral is switched for isolation but does not carry a protective device.

Frequently asked questions

Does the 5SQ2560-0KA32 switch the neutral?

Yes — it is a 1P+N design where the neutral pole is switched for isolation but does not carry overcurrent protection. The trip unit acts only on the phase pole.

MPN