Siemens 5SQ2570-0KA16 — 1-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2570-0KA16 MCB, 2-pole 1P+N, C-curve 16 A

MPN5SQ2570-0KA16

Siemens SENTRON 5SQ2570-0KA16 miniature circuit breaker, 2-pole 1P+N, C-curve, 16 A, 3 kA breaking capacity per EN 60898 and IEC 60947-2, 240 V AC, 50 Hz, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2570-0KA16 — Identification
ParameterValue
Brand nameSENTRON
Number of poles2
5SQ2570-0KA16 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2570-0KA16 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2570-0KA16 — Environmental
ParameterValue
IP protection classIP20
5SQ2570-0KA16 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)1P+N
Circuit-breaker (Design)5SQ
Current (at AC)16 A
Acc. to IEC 60947-2 / rated value3 kA
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The Siemens SENTRON 5SQ2570-0KA16 is a 2-pole miniature circuit breaker with 1P+N configuration, rated 16 A at 240 V AC, 50 Hz, with a C tripping characteristic. The 55 mm installation depth and 2 width units fit standard DIN-rail enclosures. IP20 finger-safe terminals are adequate for enclosed panel mounting.

Panel-builder commissioning notes

Neutral conductor switching is integrated, so the neutral bar is opened and closed with the protected pole. This eliminates the need for a separate neutral disconnect in single-phase final sub-circuits where the installation standard requires both phase and neutral interruption. Verify that the neutral terminal accepts the conductor cross-section you are running — the evidence does not list the terminal capacity, so confirm against the physical marking before terminating. Energy limiting class 3 indicates the breaker limits let-through energy effectively under fault conditions, which aids downstream device coordination.

Frequently asked questions

What does 1P+N mean on this breaker?

1P+N means one pole is protected (overcurrent sensing and interruption) and the neutral pole is switched (opens and closes with the protected pole) but not protected. This is common in single-phase final circuits where the neutral must be disconnected for isolation.