Skip to main content
Siemens 5SQ2570-0KA32 — 1-Pole MCB (DIN Rail)

SENTRON 5SQ2570-0KA32 MCB, 2-pole, C-curve, 32 A, 3 kA

MPN5SQ2570-0KA32

SENTRON 5SQ2570-0KA32, miniature circuit breaker, 2-pole (1P+N), C-curve, 32 A, 3 kA breaking capacity, IP20, 55 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2570-0KA32 — Identification
ParameterValue
Brand nameSENTRON
Number of poles2
5SQ2570-0KA32 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2570-0KA32 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2570-0KA32 — Environmental
ParameterValue
IP protection classIP20
5SQ2570-0KA32 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)1P+N
Circuit-breaker (Design)5SQ
Current (at AC)32 A
Acc. to IEC 60947-2 / rated value3 kA
Supply voltage (at AC)240 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The SENTRON 5SQ2570-0KA32 is a 2-pole (1P+N) miniature circuit breaker with a C-curve tripping characteristic, rated 32 A at 240 V AC, 50 Hz. It switches the neutral conductor alongside the line, so it's a single-module-width breaker that isolates both poles when it trips — no separate neutral bar needed in the distribution board. The 3 kA breaking capacity (per EN 60898 and IEC 60947-2) covers residential and light commercial fault levels; the C-curve (5 to 10 times rated current) handles motor inrush and lighting loads without nuisance tripping.

Overvoltage category III means it's rated for fixed-installation mains (distribution level, not sub-distribution).

Frequently asked questions

Where can I buy 5SQ2570-0KA32?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the breaking capacity of 5SQ2570-0KA32?

3 kA per both EN 60898 and IEC 60947-2, at 240 V AC.

Does 5SQ2570-0KA32 switch the neutral?

Yes, the product function includes neutral conductor switching — it's a 1P+N design that disconnects both line and neutral when it trips.

How does 5SQ2570-0KA32 compare to 5SU9304-1KK32?

The 5SU9304-1KK32 is an RCBO (RCD + MCB) with the same 32 A, C-curve, but a 10 kA breaking capacity and additional 30 mA residual-current protection. It's deeper (70 mm vs 55 mm) and wider (1 width unit vs 2). If you need RCD protection and have the panel depth, the 5SU9304-1KK32 is a functional upgrade; if you only need overcurrent protection and want to save space, stick with the 5SQ2570-0KA32.

MPN
5SQ2570-0KA32