Skip to main content
Siemens 5SQ2570-2YA02 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2570-2YA02 MCB, 2-Pole C 2A 400V AC

MPN5SQ2570-2YA02

Siemens SENTRON 5SQ series miniature circuit breaker, 5SQ2570-2YA02, 2-pole, C-curve 2 A, 3 kA breaking capacity per EN 60898, 400 V AC, 55 mm depth, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SQ2570-2YA02 — Identification
ParameterValue
Brand nameSENTRON
5SQ2570-2YA02 — Electrical
ParameterValue
Number of poles2
5SQ2570-2YA02 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SQ2570-2YA02 — Mechanical
ParameterValue
Installation depth55 mm
Protection degree (IP)IP20
5SQ2570-2YA02 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)2 A
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The Siemens SENTRON 5SQ2570-2YA02 is a 2-pole miniature circuit breaker with C-curve tripping characteristic, rated 2 A at 400 V AC and 3 kA breaking capacity per EN 60898. It switches both line and neutral conductors, making it a 1+N-pole device in a 2-module width package. The IP20 finger-safe terminals suit enclosure-mounting in distribution boards or sub-panels.

Energy limiting class 3 means it restricts let-through energy during a fault, which helps with downstream device coordination. Neutral conductor switching (the N pole opens and closes with the line pole) provides full isolation on both conductors when the breaker is off — useful in TN or TT systems where switching the neutral is required by local code.

The 55 mm installation depth fits standard distribution board profiles. Two width units (36 mm) on the rail.

Frequently asked questions

What is the breaking capacity of 5SQ2570-2YA02?

3 kA rated breaking capacity per EN 60898 at 400 V AC.

Does 5SQ2570-2YA02 switch the neutral?

Yes, it switches both line and neutral conductors — the neutral pole opens and closes with the line pole.

Where can I buy 5SQ2570-2YA02?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between 5SQ2570-2YA02 and 5SQ2570-2YA04?

The only difference is the current rating: 5SQ2570-2YA02 is 2 A, while 5SQ2570-2YA04 is 4 A. Both share the same 2-pole C-curve design, 3 kA breaking capacity, 400 V AC rating, and 55 mm depth — so the 4 A version drops into the same panel footprint without rewiring.

MPN
5SQ2570-2YA02