Skip to main content
Siemens 5SQ2570-2YA04 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2570-2YA04 MCB, 2P, C 4A, 3 kA

MPN5SQ2570-2YA04

Siemens SENTRON 5SQ series miniature circuit breaker, 5SQ2570-2YA04, 2-pole (1+N), C-curve 4 A, 3 kA breaking capacity per EN 60898, 400 V AC, 50 Hz, IP20, neutral conductor switching.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SQ2570-2YA04 — Identification
ParameterValue
Brand nameSENTRON
5SQ2570-2YA04 — Electrical
ParameterValue
Number of poles2
5SQ2570-2YA04 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SQ2570-2YA04 — Mechanical
ParameterValue
Installation depth55 mm
Protection degree (IP)IP20
5SQ2570-2YA04 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)4 A
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

The Siemens SENTRON 5SQ2570-2YA04 is a 2-pole miniature circuit breaker (1+N) rated 4 A with a C tripping characteristic, designed for 400 V AC, 50 Hz systems. The 3 kA breaking capacity per EN 60898 covers most domestic fault levels; for industrial panels with higher prospective short-circuit current, you'd step up to the 6 kA or 10 kA class in the same SENTRON 5SQ family.

Compared to the 3-pole 5SQ2370-2YA04 (same 4 A C-curve, same 3 kA breaking capacity, same 55 mm depth), this 2-pole unit adds neutral switching and occupies 2 width units instead of 3. The 5SQ2370-2YA04 does not switch the neutral — it's a 3-pole device for three-phase loads without neutral. If your panel was laid out for the 3-pole variant, the 2-pole 5SQ2570-2YA04 will not drop in without rewiring: the pole count and busbar arrangement differ. For a 4-pole alternative with neutral switching at 16 A, see the 5SQ2670-2YA16.

Two width units (18 mm each) means a 36 mm DIN rail footprint. The C-curve (5–10× In) handles motor inrush and transformer loads better than a B-curve; for purely resistive lighting or heating circuits, a B-curve would trip faster on short-circuit but the C-curve is the common choice for mixed loads.

Frequently asked questions

Where can I buy 5SQ2570-2YA04 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the closest functional second-source for 5SQ2570-2YA04?

The closest functional peer is the 3-pole 5SQ2370-2YA04 (same 4 A C-curve, same 3 kA breaking capacity), but it does not switch the neutral and occupies 3 width units. For a 4-pole version with neutral switching at 16 A, consider the 5SQ2670-2YA16.

Will 5SQ2570-2YA04 drop into a panel specified around 5SQ2370-2YA04 without rewiring?

No — the 2-pole 5SQ2570-2YA04 has a different pole count and busbar arrangement than the 3-pole 5SQ2370-2YA04. It will not drop in without rewiring.

MPN
5SQ2570-2YA04