Siemens 5SQ2570-2YA32 — 1-Pole MCB (DIN Rail)

Siemens 5SQ2570-2YA32 SENTRON MCB, 2P C 32A, 3kA

MPN5SQ2570-2YA32

Siemens SENTRON 5SQ2570-2YA32 miniature circuit breaker, 2-pole (1P+N), C-curve, 32 A, 3 kA per EN 60898, 400 V AC, 50 Hz, IP20, pollution degree 3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2570-2YA32 — Identification
ParameterValue
Brand nameSENTRON
Number of poles2
5SQ2570-2YA32 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2570-2YA32 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2570-2YA32 — Environmental
ParameterValue
IP protection classIP20
Pollution degree3
5SQ2570-2YA32 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Operating current (at AC)32 A
Product function (neutral conductor switching)Yes

Product details

Siemens 5SQ2570-2YA32 — SENTRON 2P MCB, C 32 A, 3 kA

The Siemens 5SQ2570-2YA32 is a SENTRON miniature circuit breaker (MCB) with 2 poles (1P+N), a C tripping characteristic, and a 32 A rated operating current at 400 V AC, 50 Hz. The neutral pole switches integrally — the product function includes neutral conductor switching — so this unit suits single-phase or split-phase panels where both line and neutral need isolation on overcurrent.

Energy limiting class 3 means it restricts let-through energy well enough to coordinate with downstream equipment in a selective scheme. The 55 mm installation depth and 2 width units (36 mm at standard 18 mm/module) fit standard DIN-rail enclosures — check gland plate depth if the panel is shallow.

Panel integration

IP20 with connected conductors — the front is finger-safe but the terminals require the panel cover for full protection. The 55 mm installation depth leaves clearance in most 80 mm deep enclosures; verify against the gland plate or backplate depth if the panel is tight. Supply voltage can be connected top or bottom; the neutral pole is switched, so mark the neutral bar accordingly.

Frequently asked questions

What is the breaking capacity of 5SQ2570-2YA32?

3 kA per EN 60898 at 400 V AC. This is the rated short-circuit capacity for the MCB under standard test conditions — suitable for final circuits where the prospective fault current stays at or below 3 kA.

What does the C-curve mean on this MCB?

The C tripping characteristic (class C) means magnetic trip occurs between 5× and 10× In (160 A to 320 A for this 32 A unit). This handles moderate inrush from small motors, transformers, or capacitive loads without nuisance tripping while still clearing low-impedance faults quickly.

Does 5SQ2570-2YA32 switch the neutral?

Yes, the product function includes neutral conductor switching — both poles (1P+N) open and close together. This provides full isolation on overcurrent or manual switching.

Where can I buy 5SQ2570-2YA32?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.