Skip to main content
Siemens 5SQ2570-2YA50 — 1-Pole MCB (DIN Rail)

SENTRON 5SQ2570-2YA50 MCB, 2P C 50A, 3kA, 400V AC

MPN5SQ2570-2YA50

SENTRON 5SQ series miniature circuit breaker, 5SQ2570-2YA50, 2-pole (1P+N), C tripping characteristic, 50 A rated current, 3 kA breaking capacity per EN 60898, 400 V AC, 50 Hz, IP20, 2 width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2570-2YA50 — Identification
ParameterValue
Brand nameSENTRON
Number of poles2
5SQ2570-2YA50 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)3 kA
Overvoltage category3
5SQ2570-2YA50 — Mounting & Connection
ParameterValue
Installation depth55 mm
5SQ2570-2YA50 — Environmental
ParameterValue
IP protection classIP20
5SQ2570-2YA50 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)50 A
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

SENTRON 5SQ2570-2YA50 — 2-pole C-curve MCB, 50 A, 3 kA

It carries a C tripping characteristic at 50 A rated current, breaking capacity rated 3 kA per EN 60898 at 400 V AC, 50 Hz.

Occupies 2 width units on a standard DIN rail, with 55 mm installation depth. Overvoltage category 3 and energy limiting class 3 place it in the standard residential and light commercial coordination tier.

Drop-in vs sibling ratings

Same physical footprint, terminal layout, and DIN-rail clip as the 5SQ2570-2YA04 (4 A C-curve) and 5SQ2270-2YA04 / 5SQ2270-2YA03 (3 A C-curve). All share 2-pole 1P+N construction, 55 mm depth, IP20, and 3 kA breaking capacity. The only difference is the thermal-magnetic trip rating — a panel wired for a lower-rated sibling can accept the 50 A unit without rewiring, provided the downstream conductors and load are sized for 50 A.

Frequently asked questions

What is the breaking capacity of 5SQ2570-2YA50?

Rated 3 kA per EN 60898 at 400 V AC, 50 Hz — sufficient for standard residential and light commercial fault levels.

Will 5SQ2570-2YA50 drop into a panel that was specified around 5SQ2570-2YA04 without rewiring?

Yes — same 2-pole 1P+N footprint, same DIN-rail clip, same 55 mm depth. The only difference is the 50 A trip rating versus 4 A; verify downstream conductor sizing and load before substitution.

Where can I buy 5SQ2570-2YA50?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — send an RFQ for a firm price and lead time.

MPN
5SQ2570-2YA50