Skip to main content
Siemens 5SQ2670-0KA01 — 4-Pole MCB (DIN Rail)

SENTRON 5SQ2670-0KA01 4P MCB, 1A, C-Curve, 3kA, 400V AC

MPN5SQ2670-0KA01

Siemens SENTRON 5SQ series, 5SQ2670-0KA01, 4-pole (3P+N) miniature circuit breaker, 1 A rated current, C tripping characteristic, 3 kA breaking capacity, 400 V AC, 50 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SQ2670-0KA01 — Identification
ParameterValue
Type / order code5SQ
Brand nameSENTRON
5SQ2670-0KA01 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC1 A
Voltage typeAC/DC
5SQ2670-0KA01 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608983 kA
Rated breaking capacity, per IEC 60947-23 kA
Overvoltage category3
Degree of protection (IP)IP20
Neutral conductor switchingYes
5SQ2670-0KA01 — Mechanical
ParameterValue
Width in modular units3
Installation depth55 mm

Product details

The Siemens SENTRON 5SQ2670-0KA01 is a 4-pole miniature circuit breaker (3P+N) with a 1 A rated current at AC, C tripping characteristic, and 3 kA breaking capacity per both EN 60898 and IEC 60947-2. Rated at 1 A with a C-curve, this MCB is sized for protecting small branch circuits — think control transformers, signal-conditioning supplies, or instrumentation loops — where the inrush from a transformer or capacitive load would nuisance-trip a B-curve.

Peer comparison

The closest functional peer in the 5SQ series is the 5SQ2670-0KA15, which shares the same 4-pole 3P+N configuration, C-curve, 3 kA breaking capacity, 400 V AC rating, and 55 mm depth. The only difference is the current rating: 15 A vs. 1 A. Both occupy 3 width units and switch the neutral. If your panel was specified around the 5SQ2670-0KA15, the 5SQ2670-0KA01 drops into the same DIN-rail slot and busbar arrangement without rewiring — just confirm the branch-circuit load rating.

Integration notes

The 55 mm depth leaves clearance for a standard enclosure door with a 60 mm back-panel depth. Wire termination accepts up to 25 mm² for the line and load side; torque to 2.5 Nm per the terminal marking. Energy limiting class 3 indicates the breaker limits let-through energy to a level that protects downstream components under short-circuit conditions. IP20 rated: suitable for dry indoor panels only.

Frequently asked questions

Does 5SQ2670-0KA01 switch the neutral?

Yes, the product function includes neutral conductor switching, so all four poles — three phases plus neutral — open simultaneously.

Will 5SQ2670-0KA01 drop into a panel specified for 5SQ2670-0KA15?

Yes, both share the same 4-pole 3P+N configuration, C-curve, 3 kA breaking capacity, 400 V AC rating, 55 mm depth, and 3 width units. The only difference is the current rating (1 A vs. 15 A), so it fits the same DIN-rail slot and busbar without rewiring — just verify the branch-circuit load matches the 1 A rating.

MPN
5SQ2670-0KA01