Skip to main content
Siemens 5SQ2670-0KA05 — 4-Pole MCB (DIN Rail)

SENTRON 5SQ2670-0KA05 MCB, 4-Pole, C-Curve, 5 A, 3 kA

MPN5SQ2670-0KA05

SENTRON 5SQ2670-0KA05, 4-pole (3P+N) miniature circuit breaker, C-curve, 5 A rated current, 3 kA breaking capacity per EN 60898 at 400 V AC, 50 Hz, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SQ2670-0KA05 — Identification
ParameterValue
Type / order code5SQ
Brand nameSENTRON
5SQ2670-0KA05 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC5 A
Voltage typeAC/DC
5SQ2670-0KA05 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608983 kA
Overvoltage category3
Degree of protection (IP)IP20
Neutral conductor switchingYes
5SQ2670-0KA05 — Mechanical
ParameterValue
Width in modular units3
Installation depth55 mm
5SQ2670-0KA05 — Other specifications
ParameterValue
Energy limiting class3
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz

Product details

Integrator note — SENTRON 5SQ2670-0KA05

The SENTRON 5SQ2670-0KA05 is a 4-pole miniature circuit breaker in a 3P+N configuration, meaning it switches all three phases and the neutral conductor — the neutral pole is switched, not just solid-linked. Rated 5 A with a C-curve tripping characteristic, it's sized for moderate inrush loads like small motor starters or lighting banks where the start-up surge sits between 5× and 10× the rated current. The 3 kA breaking capacity at 400 V AC (per EN 60898) covers standard distribution board fault levels; if your panel SCCR exceeds that, you'll need an upstream current-limiting device. The 55 mm installation depth and 3 width units (roughly 54 mm on a standard DIN rail) mean it fits the same cutout as other 4-pole SENTRON T55 breakers — no panel rework for a swap.

Panel integration and protection class

Rated IP20 — suitable for installation inside a closed distribution board or enclosure where no water ingress is expected. Energy limiting class 3 indicates it restricts let-through energy during a fault, which helps with downstream device coordination.

Frequently asked questions

What is the number of poles on 5SQ2670-0KA05?

It has 4 poles in a 3P+N configuration — three phase poles plus a switched neutral pole.

Will 5SQ2670-0KA05 drop into a panel built for 5SQ2670-0KA15?

Yes — both share the same 4-pole 3P+N footprint, 55 mm depth, 3 width units, and DIN-rail mounting. The only difference is the current rating: 5 A on this part versus 15 A on the -0KA15. No rewiring or panel modification needed.

What type of voltage does 5SQ2670-0KA05 accept?

It accepts AC/DC voltage, with a rated AC supply of 400 V at 50 Hz.

Where can I buy 5SQ2670-0KA05 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is listed here.

MPN
5SQ2670-0KA05