Siemens 5SQ2670-0KA40 — Miniature Circuit Breakers (MCB)

SENTRON 5SQ2670-0KA40 MCB, 4P, 40 A, C-curve, 3 kA

MPN5SQ2670-0KA40

SENTRON 5SQ2670-0KA40, 4-pole MCB, 40 A, C-curve, 3 kA breaking capacity per EN 60898, 400 V AC, 50 Hz, IP20, 3 width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2670-0KA40 — Ratings
ParameterValue
Overvoltage category3
5SQ2670-0KA40 — Other specifications
ParameterValue
Poles4
Type of voltageAC/DC
Installation depth55 mm
Protection class IPIP20
Energy limiting class3
Number of width units3
Number of poles (Note)3P+N
Circuit-breaker (Design)5SQ
Current (at AC)40 A
Tripping characteristic classC
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

It carries a 40 A rated current at 400 V AC, 50 Hz, with a C tripping characteristic — meaning it holds up to 5–10× rated current for short overloads and trips faster on higher faults, typical for motor and general-purpose branch circuits.

Snap-on DIN-rail mount, 3 width units (approx. 54 mm), installation depth 55 mm. IP20 finger-safe terminals. Overvoltage category 3 and energy limiting class 3 — suitable for fixed-installation distribution boards where the breaker provides both overload and short-circuit protection downstream. The switched neutral (3P+N) means the neutral is disconnected when the breaker is off, which some local wiring codes require for final circuits.

Frequently asked questions

What is the breaking capacity of 5SQ2670-0KA40?

3 kA per EN 60898 at 400 V AC, which is the standard rating for this class of MCB in residential and light commercial distribution boards.

Will 5SQ2670-0KA40 drop into a panel specified around 5SQ2670-0KA15 without rewiring?

Yes — both are 4-pole 3P+N, same 55 mm depth, same 3 width units, same C-curve. The only difference is the 40 A rating versus 15 A. The panel busbar and wiring must be sized for 40 A; if the existing circuit is wired for 15 A, the breaker will not protect the smaller conductors.

Where can I buy 5SQ2670-0KA40?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
5SQ2670-0KA40