Skip to main content
Siemens 5SU1156-6KV13 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1156-6KV13 FI/LS Protector, Type A, 10mA, 6kA, B

MPN5SU1156-6KV13

Siemens 5SU1156-6KV13 FI/LS protector, Type A (PSE/SSF), D=70mm, IΔN 10mA, 6kA, 1+N-pole, B 13A.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Product details

The Siemens 5SU1156-6KV13 is a combined residual current device and miniature circuit breaker (RCBO) — an FI/LS protector — in a single 1+N-pole module. It carries a Type A (PSE/SSF) residual current sensitivity of 10 mA and a B-curve overcurrent trip at 13 A, with a short-circuit breaking capacity of 6 kA. The 70 mm depth is standard for Siemens 5SU series RCBOs, fitting directly into the same DIN-rail distribution boards as the SENTRON family.

The 10 mA IΔN is the key spec for personnel protection in wet or medical locations — it's the threshold that catches leakage through the human body before fibrillation risk escalates. Type A detection means it responds to pulsating DC fault currents (rectified from AC waveforms), not just pure sinusoidal AC; that covers modern switched-mode power supplies, variable-speed drives, and LED drivers. The B-curve overcurrent trip at 13 A means the magnetic release operates at 3–5× In (39–65 A), sized for resistive and lightly inductive loads like lighting circuits or control transformers — not for motor starting inrush. In a panel with higher fault capacity upstream, the 5SU1156-6KV13 needs a back-up fuse or upstream MCB with a lower let-through to ensure coordination.

The 1+N-pole format occupies a single module width (18 mm per pole, so 36 mm total for the 1P+N unit). Neutral is switched and protected — the right-side terminal is the switched neutral. Wire size: 1–25 mm² for the line/load terminals, with a combined busbar fork compatible with the Siemens 5SU/5SL busbar system.

Frequently asked questions

Where can I buy the 5SU1156-6KV13?

The 5SU1156-6KV13 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the 5SU1156-6KV13 used for?

It is a combined RCD/MCB (RCBO) for final subcircuit protection — the 10 mA Type A RCD protects against AC and pulsating DC earth faults, while the B-curve 13 A MCB protects against overload and short circuit. Typical use is in residential, commercial, or light industrial distribution boards where personnel protection is required for circuits feeding socket outlets, lighting, or equipment with electronic loads.

What compliance documentation does Siemens provide for this RCBO?

The part is designed to EN 61009-1 and carries CE marking for the European market. Siemens typically provides a Declaration of Conformity covering the Low Voltage Directive and EMC Directive. RoHS and REACH compliance documentation is available from Siemens on request.

MPN
5SU1156-6KV13