Siemens 5SU1156-7KV10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1156-7KV10 FI/LS Protector Type A, 10A C, 10mA, 6

MPN5SU1156-7KV10

Siemens 5SU1156-7KV10 FI/LS-protector Type A (PSE/SSF), 1+N-pole, C 10A, IΔn 10mA, 6kA breaking capacity, 70mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 5SU1156-7KV10 is a combined residual-current device and miniature circuit breaker — an FI/LS-protector — in a single 1+N-pole module. It integrates Type A earth-leakage detection (sensitive to pulsating DC residual currents up to 10 mA) with a C-curve overcurrent trip set at 10 A, all within a 70 mm wide DIN-rail housing. The 10 mA residual sensitivity (IΔn) is the key differentiator here: it is far more sensitive than the typical 30 mA RCD used for socket-outlet protection. A 10 mA device is specified for circuits where even a small leakage current poses a risk — for example, in medical locations, wet areas, or circuits supplying equipment with low leakage tolerance. The Type A classification means it detects both sinusoidal AC residual currents and pulsating DC residuals, which covers most modern electronic loads (switched-mode power supplies, variable-speed drives, LED drivers) that generate half-wave fault currents.

Deployment context

The 1+N-pole format (switched phase plus switched neutral) is common in UK and European final-circuit installations where the neutral is isolated when the device trips, ensuring full disconnection.

Frequently asked questions

Where can I buy the 5SU1156-7KV10 and get a price?

This part is sourced to order against an RFQ through our Siemens franchise channel. Submit an RFQ for current pricing and availability confirmation — stock and price are confirmed at quote time.

What does the 10 mA residual sensitivity mean for my application?

The 10 mA IΔn is a high-sensitivity setting intended for circuits where even small leakage currents must be detected — medical locations, wet environments, or equipment with low leakage tolerance. It is more sensitive than the standard 30 mA RCD used for general socket outlets.

What is the breaking capacity of the 5SU1156-7KV10?

The device is rated for 6 kA breaking capacity per IEC/EN 61009, which is the standard short-circuit rating for final-circuit protection in most domestic and light commercial TN/TT distribution boards.

MPN
5SU1156-7KV10