Skip to main content
Siemens 5SU1322-7KC40 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU1322-7KC40 RCBO, 40 A, 30 mA, C-curve, 50

MPN5SU1322-7KC40

Siemens SENTRON 5SU1322-7KC40 RCBO, 2-pole, Type A, 30 mA residual current, C-curve, In 40 A, Un AC 400 V, 50 kA per EN 60898.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1322-7KC40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1322-7KC40 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1322-7KC40 — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
5SU1322-7KC40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1322-7KC40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Type A detection catches pulsating DC fault currents from single-phase rectified loads — common with switching power supplies, LED drivers, and variable-speed drives — so it's the right choice for mixed-load final circuits.

At 2 width units and 70 mm installation depth, this RCBO fits standard distribution boards. That's wide enough for most indoor panel environments, including non-climate-controlled electrical rooms. The IP20 rating applies only when the distribution board is installed and conductors are connected — so don't leave it exposed during commissioning; the front face offers touch protection (finger-safe terminals per the product feature), but the back and sides rely on the enclosure.

Frequently asked questions

What is the closest functional second-source for 5SU1322-7KC40 — does 5SL6563-7BB drop in?

The 5SL6563-7BB is a different product class (a miniature circuit breaker, not an RCBO) and does not carry the residual-current protection this RCBO provides. It is not a functional substitute; the 5SU1322-7KC40 is the combined RCBO with 30 mA Type A RCD protection that the 5SL series lacks.

Will 5SU1322-7KC40 drop into a panel specified around 5SL6563-7BB without rewiring?

No — the 5SL6563-7BB is a 2-pole MCB with no residual-current protection. The 5SU1322-7KC40 is an RCBO that requires a neutral connection for the RCD electronics and switched neutral. The panel wiring and busbar arrangement would need modification.

MPN
5SU1322-7KC40