Siemens 5SU1323-1BB10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1323-1BB10 SENTRON RCBO, 10 A, 30 mA, Type AC, C-

MPN5SU1323-1BB10

Siemens SENTRON series RCBO, 2-pole, 10 A rated current, 30 mA Type AC residual current, C-curve trip characteristic, 4.5 kA breaking capacity per EN 60898, 15 kA per IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1323-1BB10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1323-1BB10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1323-1BB10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum75 °C
Minimum-40 °C
Installation depth70 mm
5SU1323-1BB10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1323-1BB10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Breaking capacity is 4.5 kA per EN 60898 for residential and commercial distribution boards, and 15 kA per IEC 60947-2 for industrial panel applications — the higher figure gives headroom for fault currents at the service entrance.

Type AC residual current detection means this RCBO responds to sinusoidal AC fault currents only — suitable for general-purpose circuits feeding resistive, inductive, and electronic loads where no pulsed DC fault signature is expected. The 30 mA trip threshold provides supplementary protection against electric shock per IEC 60364, covering most socket-outlet and lighting circuits in residential and light commercial installations. Rated insulation voltage (Ui) of 440 V and overvoltage category III confirm this RCBO is rated for fixed-installation distribution boards where transient overvoltages up to 4 kV (surge voltage resistance) are expected. The 50 Hz operating frequency matches standard mains supplies across Europe and Asia.

Supply can enter from either top or bottom, and the neutral conductor is switched internally (no separate neutral bar required downstream). Touch protection is integrated on the terminals.

Frequently asked questions

What is the breaking capacity of 5SU1323-1BB10?

4.5 kA per EN 60898 for residential distribution boards, and 15 kA per IEC 60947-2 for industrial panel applications.

What is the difference between 5SU1323-1BB10 and the 5SY series RCBOs?

The 5SY series (e.g. 5SY4332-7CV) are MCBs without residual current protection, while the 5SU1323-1BB10 integrates both overcurrent and 30 mA residual current protection in a single 4 MWU package. If your panel requires separate RCD and MCB, the 5SY plus a separate RCD block is the alternative; if you need the combined RCBO footprint, the 5SU is the direct fit.

Where can I buy 5SU1323-1BB10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SU1323-1BB10