Siemens 5SU1323-1WM06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1323-1WM06 SENTRON RCBO, 2P C 6A, 30mA, 4.5kA

MPN5SU1323-1WM06

Siemens SENTRON RCBO, Type AC, 2-pole, C-curve 6 A, 30 mA residual current, 4.5 kA (EN 60898) / 25 kA (IEC 60947-2), 4 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1323-1WM06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1323-1WM06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1323-1WM06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum75 °C
Minimum-40 °C
Installation depth70 mm
5SU1323-1WM06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1323-1WM06 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value6 A

Product details

Siemens 5SU1323-1WM06 SENTRON RCBO — 2-pole, C-curve 6 A, 30 mA, Type AC

It protects a 2-pole (2P) final circuit against both overcurrents (C-curve, rated 6 A) and earth faults (30 mA, Type AC). Rated breaking capacity is 4.5 kA per EN 60898 and 25 kA per IEC 60947-2 — the higher figure applies when the device is used as a standalone circuit breaker under industrial panel rules. Residual-current detection is Type AC (sinusoidal AC fault currents only), at the standard 30 mA threshold for personal protection. The neutral conductor is switched internally, so this RCBO can serve as the main disconnection means for a 2-wire single-phase circuit.

Occupies 4 modular-width units (4 MW) on a DIN rail. Installation depth is 70 mm — verify enclosure depth clearance, especially in shallow consumer units. Touch protection is built in (IP20 with distribution board installed and conductors connected). Operates on 50 Hz AC supply only. Rated operational current is 6 A at AC. Overvoltage category III (distribution-level) and pollution degree 2 (non-condensing, typical for clean indoor panels).

Halogen-free and silicon-free construction. Surge current withstand is 1 kA (8/20 µs waveform). Energy limitation class 3.

Frequently asked questions

What is the breaking capacity of the 5SU1323-1WM06?

Rated breaking capacity is 4.5 kA per EN 60898 and 25 kA per IEC 60947-2.

What is the difference between the 5SU1323-1WM06 and the 5SU9304-1KK32?

The 5SU9304-1KK32 is a 1P+N 32 A RCD-operated circuit breaker (not a combined RCBO) with 10 kA breaking capacity per both standards, in a 1 MW width. The 5SU1323-1WM06 is a 2-pole 6 A RCBO with integral overcurrent protection, 4 MW width, and higher IEC 60947-2 breaking capacity (25 kA). They are not direct drop-in replacements — the 5SU1323-1WM06 provides combined overcurrent and earth-fault protection in a single device, while the 5SU9304-1KK32 is a standalone RCD requiring a separate MCB upstream.

What is the operating temperature range for the 5SU1323-1WM06?

Ambient temperature range is -40 °C to 75 °C.

Where can I buy the 5SU1323-1WM06?

Sourced and quoted to order against an RFQ through independent distribution — availability and current pricing confirmed at quote time.

MPN
5SU1323-1WM06