Skip to main content
Siemens 5SU1323-1WM10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1323-1WM10 SENTRON RCBO, 2P C10A 30mA AC, 4.5kA

MPN5SU1323-1WM10

Siemens SENTRON 5SU1323-1WM10 RCBO, 2-pole, 10 A rated, C tripping characteristic, 30 mA AC fault current, 4.5 kA (EN 60898) / 15 kA (IEC 60947-2), 4 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1323-1WM10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1323-1WM10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1323-1WM10 — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
5SU1323-1WM10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1323-1WM10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1323-1WM10 is a 2-pole RCBO (residual-current circuit breaker with overcurrent protection) from the SENTRON 5SU1 series, combining a 10 A C-curve MCB with a 30 mA AC-type RCD in a single 4-module-wide unit. It is designed for final-circuit protection in residential and commercial distribution boards, providing both overcurrent and earth-fault protection in one device.

The 30 mA residual-current trip threshold provides supplementary protection against electric shock; it is the standard level for general-purpose socket circuits in most IEC-based wiring regulations. Breaking capacity is rated 4.5 kA per EN 60898 for domestic-type MCBs and 15 kA per IEC 60947-2 for industrial-type circuit breakers — the higher figure applies when the device is used in an industrial distribution board with higher prospective fault current.

The 70 mm installation depth and 4-module width are typical for a 2-pole RCBO — check the board's gutter space and door clearance before committing. Screw-type terminals accept solid or stranded conductors from 1.5 to 25 mm²; tighten to 2.5–3 N·m. The IP20 rating applies only when the distribution board is installed and conductors are connected — this is a panel-internal device, not for wet or outdoor locations.

Frequently asked questions

What are the key ratings of the 5SU1323-1WM10?

It is a 2-pole RCBO rated 10 A, C-curve, 30 mA AC-type residual current, with breaking capacities of 4.5 kA (EN 60898) and 15 kA (IEC 60947-2).

Where can I buy the 5SU1323-1WM10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What conductor sizes does the 5SU1323-1WM10 accept?

The screw terminals accept solid or stranded conductors from 1.5 to 25 mm².

MPN
5SU1323-1WM10