Skip to main content
Siemens 5SU1324-1KK82 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1324-1KK82 SENTRON RCBO, 2P, 125 A, 30 mA, C-curv

MPN5SU1324-1KK82

Siemens SENTRON 5SU1324-1KK82, 2-pole RCBO, 125 A rated current, 30 mA residual fault current, C tripping characteristic, 10 kA breaking capacity, 7 MW.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-1KK82 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-1KK82 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-1KK82 — Mechanical
ParameterValue
Mounting positionany
Width in modular units7
Maximum75 °C
Minimum-40 °C
Installation depth70 mm
5SU1324-1KK82 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-1KK82 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1324-1KK82 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) from the SENTRON family, rated 125 A at AC with a 30 mA residual fault current and C-curve trip characteristic. It breaks fault currents up to 10 kA per EN 60898 and IEC 60947-2, so it handles typical commercial and industrial branch-circuit faults without upstream coordination issues.

Thermal derating and installation constraints

At 40 °C ambient the 125 A rating derates to 115.62 A; at 50 °C it drops to 106.25 A, and at 60 °C to 96.25 A. That means a panel running near 50 °C loses roughly 15% of the headline capacity — factor that into the load schedule before committing the BOM line. The unit occupies 7 modular width units (roughly 126 mm) on a DIN rail and mounts in any position, with a 70 mm installation depth.

Halogen-free and silicon-free construction suits installations where outgassing or contamination risk matters (e.g., clean rooms, medical environments). Operating temperature range spans -40 °C to 75 °C, with max 95% humidity influence.

Frequently asked questions

What is 5SU1324-1KK82's rated breaking capacity?

It is rated 10 kA per both EN 60898 and IEC 60947-2, covering branch-circuit fault interruption up to that level.

What does the 30 mA residual current rating mean for this RCBO?

The 30 mA trip threshold provides additional protection against electric shock in final circuits — it detects earth leakage currents as low as 30 mA and disconnects within the instantaneous response time.

Where can I buy 5SU1324-1KK82?

This part is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time.

MPN
5SU1324-1KK82