Siemens SENTRON 5SU1324-6FA06 RCBO, 2-pole instantaneous, B tripping characteristic, 6 A rated at 30 °C, 10 kA breaking capacity per EN 60898, 35 kA per IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-6FA06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-6FA06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-6FA06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum75 °C
Minimum-40 °C
Width54 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1324-6FA06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-6FA06 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It combines a B-curve miniature circuit breaker (MCB) and a residual current device (RCD) in one 3-module-width unit. The residual current element provides earth-fault protection for personnel and equipment. The EN 60898 rating covers domestic and commercial final circuits; the IEC 60947-2 rating applies when the device is used in industrial distribution boards with higher prospective fault levels. Energy limitation class 3 keeps let-through energy low enough to protect downstream wiring.

The 6 A rating is only valid at 30 °C ambient. Inside a closed distribution board, ambient temperature is often higher. At 40 °C the continuous rating drops to 5.7 A; at 50 °C to 5.4 A; at 60 °C to 5.1 A; at 70 °C to 4.62 A. Operating frequency is 50 Hz only. Supply voltage 230/240 V AC, insulation voltage 264 V.

The 5SU1324-6FA06 snaps onto DIN rail (3 module widths, 54 mm wide). Mounting position is any orientation. Feed from top or bottom — no restriction. Installation depth 70 mm; total depth 77 mm. IP20 rating applies only after the distribution board is installed and conductors connected — the device itself is not sealed for exposed locations. Halogen-free and silicon-free construction, important for clean-room or corrosive-environment installations where outgassing contaminates contacts or optics.

Frequently asked questions

How do I get current pricing and availability for 5SU1324-6FA06?

Submit an RFQ — the part is sourced through independent distribution and quoted to order. Availability and current pricing are confirmed at quote time.

What is 5SU1324-6FA06's listed depth (77 mm) on this component line?

Total depth is 77 mm; installation depth (behind the panel face) is 70 mm.

What is 5SU1324-6FA06's listed width (54 mm) on this component line?

Width is 54 mm, which corresponds to 3 modular DIN-rail units (each 18 mm).

What compliance documentation does this brand provide for 5SU1324-6FA06 (RoHS, REACH, UL, IEC)?

The device is designed to EN 60898 and IEC 60947-2. Halogen-free and silicon-free construction is declared. For specific RoHS/REACH/UL declarations, request the manufacturer's compliance documentation through an RFQ.