Skip to main content
Siemens 5SU1324-6FA13 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU1324-6FA13 RCBO, 2P, 13 A, 30 mA, Type A,

MPN5SU1324-6FA13
Active

Siemens SENTRON RCBO, 2-pole, 13 A rated, 30 mA residual, Type A, B characteristic, 10 kA per EN 60898, 3 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-6FA13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-6FA13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-6FA13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum75 °C
Minimum-40 °C
Width54 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1324-6FA13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-6FA13 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens SENTRON 5SU1324-6FA13 is a 2-pole combined residual current circuit breaker with overcurrent protection — an RCBO — rated 13 A at AC with a 30 mA residual trip threshold, Type A (pulsating DC and AC sensitive), B tripping characteristic, and a 10 kA breaking capacity per EN 60898. Type A residual detection covers sinusoidal AC faults and pulsating DC up to 6 mA smooth DC, covering most single-phase electronics loads.

Panel fit and derating

The 5SU1324-6FA13 occupies 3 modular width units (54 mm) on a DIN rail, with a depth of 77 mm and an installation depth of 70 mm — standard for a 2-pole RCBO in a SENTRON distribution board. IP20 applies only when the distribution board is installed with connected conductors, so the device itself is not sealed against dust ingress; it lives inside a closed enclosure. The thermal derating table is explicit: at 40 °C ambient the device carries 12.48 A, at 50 °C it drops to 11.96 A, and at 70 °C it's 10.01 A.

Frequently asked questions

Where can I buy 5SU1324-6FA13?

The part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the 5SU1324-6FA13's depth?

The depth is 77 mm, with an installation depth of 70 mm.

What is the 5SU1324-6FA13's width?

The width is 54 mm, which is 3 modular width units on a DIN rail.

MPN
5SU1324-6FA13