Skip to main content
Siemens 5SU1324-6FA40 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU1324-6FA40 RCBO, 2P, 40A, B-Curve, 30mA T

MPN5SU1324-6FA40
Active

Siemens SENTRON 5SU1324-6FA40, RCBO, 2-pole, 40 A, B-curve, 30 mA Type A residual current, 10 kA breaking capacity per EN 60898.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-6FA40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-6FA40 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-6FA40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum75 °C
Minimum-40 °C
Width54 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1324-6FA40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-6FA40 — Electrical
ParameterValue
Tripping Characteristic ClassB
Operational current / at AC / rated value40 A

Product details

The Siemens 5SU1324-6FA40 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) from the SENTRON series, combining a 40 A B-curve MCB and a 30 mA Type A RCD in a single 3-module-width unit. It protects against overload, short-circuit, and earth leakage in one device — saving a DIN-rail position compared to separate MCB + RCD pairs. Rated 230/240 V AC at 50 Hz, it carries 40 A at 30 °C ambient, derating to 29.2 A at 70 °C — the full thermal curve is on record so you can size for warm enclosures without guessing. The Type A residual current element detects sinusoidal AC faults plus pulsating DC fault currents — the standard requirement for circuits feeding single-phase electronics, switched-mode power supplies, and appliances with rectifiers. A pure AC-sensitive RCD would miss those pulses.

Installation and compliance

Supply can enter from top or bottom, which simplifies panel wiring when busbars run at the top. IP20 with the distribution board installed and conductors connected — normal for an enclosed panel. Degree of pollution 2 covers normal indoor environments with occasional condensation.

Frequently asked questions

What is the depth of the 5SU1324-6FA40?

The depth is 77 mm, with an installation depth of 70 mm accounting for the DIN-rail clip and wiring space.

MPN
5SU1324-6FA40