Siemens 5SU1324-6FP10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1324-6FP10 SENTRON RCBO, 10 A B-curve, 10 kA

MPN5SU1324-6FP10
Active

Siemens SENTRON RCBO, 2-pole, 10 A, B-curve, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 2 MW, IP20, -40 to 70 °C.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-6FP10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-6FP10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-6FP10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum70 °C
Minimum-40 °C
Width36 mm
Height85 mm
Depth72 mm
Installation depth70 mm
5SU1324-6FP10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-6FP10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It's not sized for motor starting; that wants a C or D curve. Either way, it clears a bolted fault without venting or welding contacts — that's the job. Temperature derating is built into the spec: 10 A at 30 °C ambient drops to 8.2 A at 70 °C. If this RCBO lives in a hot enclosure next to contactors or drives, use the 70 °C figure for the continuous load — not the 30 °C number. The operating range (-40 to 70 °C) covers outdoor cabinets in cold climates and warm panels alike.

Two modular-width units (36 mm wide) snap onto standard DIN rail. Depth is 72 mm; installation depth 70 mm. Mount in any position — no derating for orientation. Supply can land top or bottom, which saves a few minutes if you're retrofitting into a crowded enclosure and the busbar comes in from the bottom. IP20 with conductors connected and the distribution board installed — that's the usual for a panelboard. Not for washdown or outdoor exposed mounting without an enclosure.

Frequently asked questions

Where can I buy the 5SU1324-6FP10?

The 5SU1324-6FP10 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the 5SU1324-6FP10?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher IEC figure applies in industrial panels where fault current may exceed the residential standard.

Will the 5SU1324-6FP10 drop into a panel specified around a 5SY4310-7CV?

Both are 2-pole RCBOs with a 10 A B-curve rating, but the 5SY4310-7CV is a different series with different breaking capacities and dimensions. The 5SU1324-6FP10 is a 2 MW unit with 10 kA/15 kA breaking capacity; verify physical fit and coordination before substituting.

MPN
5SU1324-6FP10