Siemens 5SU1324-6FR16 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU1324-6FR16 RCBO, 2-pole, B-curve, 16 A, 3

MPN5SU1324-6FR16
Active

Siemens SENTRON RCBO, 5SU1324-6FR16, 2-pole, B-curve, 16 A, 30 mA, Type A, 10 kA (EN 60898).

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1324-6FR16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1324-6FR16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K

Mechanical

5SU1324-6FR16 — Mechanical
ParameterValue
Mounting positionAny
Width in modular units2
Maximum70 °C
Minimum-40 °C
Width36 mm
Height85 mm
Depth72 mm
Installation depth70 mm

Environmental

5SU1324-6FR16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1324-6FR16 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens SENTRON 5SU1324-6FR16 is a 2-pole residual current circuit breaker with overcurrent protection (RCBO) in the super-resistant K design, rated 16 A at AC with a B-curve tripping characteristic and 30 mA Type A residual current sensitivity.

Breaking capacity and selectivity

Rated breaking capacity is 10 kA per EN 60898 and 15 kA per IEC 60947-2, putting it in the standard residential and light commercial range for a 16 A RCBO. The higher IEC rating gives headroom for industrial panels where fault levels may exceed the EN threshold. Energy limitation class 3 means the device limits let-through energy to a level that protects downstream wiring and connected equipment during a short-circuit event.

Temperature derating and mounting

Rated 16 A at 30 °C; derates to 15.2 A at 40 °C and 13.4 A at 60 °C. In a warm enclosure the continuous load must stay under the derated value to avoid nuisance tripping. Occupies 2 modular width units (36 mm) and snaps onto DIN rail. Mounting position is any orientation, with 70 mm installation depth required behind the panel cover. Supply can enter from top or bottom.

Overvoltage category III and pollution degree 3 suit it for permanent connection to the mains supply in fixed installations. Rated insulation voltage is 500 V. Touch protection is integrated on the terminals.

Frequently asked questions

What is the breaking capacity of 5SU1324-6FR16?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher IEC figure applies when the device is certified to that standard for industrial applications.

What does the 30 mA Type A residual current rating mean?

Type A detects sinusoidal AC fault currents plus pulsating DC fault currents, covering most modern electronic loads that generate half-wave rectified leakage. The 30 mA threshold provides additional protection against fatal electric shock.

Where can I buy the 5SU1324-6FR16?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.