Skip to main content
Siemens 5SU1324-6KX06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1324-6KX06 SENTRON RCBO, 6A B-curve 30mA 2P 10kA

MPN5SU1324-6KX06
Active

Siemens SENTRON 5SU1324-6KX06 RCBO, 2-pole, B-curve, 6 A rated, 30 mA residual current, 10 kA breaking capacity per EN 60898, 35 kA per IEC 60947-2, 110/120 V AC, 3 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-6KX06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-6KX06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-6KX06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum75 °C
Minimum-40 °C
Width54 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1324-6KX06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-6KX06 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SU1324-6KX06 is a 2-pole residual current operated circuit breaker (RCBO) from the SENTRON series, combining overcurrent protection and 30 mA residual current detection in a single 3-module-width unit (54 mm wide per, 90 mm tall per, 77 mm deep per). The 30 mA residual sensitivity covers personnel protection (indirect contact) and fire prevention per IEC 60364. The 4 000 V surge voltage resistance and overvoltage category III confirm it is rated for fixed-installation mains supply, not downstream equipment-level protection.

Mounts on DIN rail in any orientation. The 70 mm installation depth plus 7 mm for the housing means it clears most 80 mm deep enclosures. IP20 rating applies only when the distribution board is installed and conductors are connected — this is a panel-internal device, not surface-mount. The 95% humidity limit is standard for enclosed electrical rooms.

Frequently asked questions

How do I get current pricing and availability for 5SU1324-6KX06?

Submit an RFQ against this order code. Pricing and stock are confirmed at quote time through independent distribution channels — no automated price or lead-time figure is published here.

Will 5SU1324-6KX06 drop into a panel specified around 5SU9354-7KK16 without rewiring?

No — the 5SU1324-6KX06 is a 2-pole RCBO (54 mm wide, 3 MW) while the 5SU9354-7KK16 is a 1P+N RCBO (36 mm wide, 2 MW) with a C-curve at 230/240 V. The pole count, voltage rating, and trip characteristic differ; the panel busbar and wiring would need reconfiguration.

What compliance documentation does Siemens provide for 5SU1324-6KX06?

The RCBO carries ratings per EN 60898 (10 kA) and IEC 60947-2 (35 kA). It is halogen-free and silicon-free. Standard Siemens declarations for RoHS and REACH are available on request with the order documentation.

MPN
5SU1324-6KX06