Siemens 5SU1324-6KX16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1324-6KX16 SENTRON RCBO, 2P B-16A 30mA, 10kA

MPN5SU1324-6KX16
Active

Siemens SENTRON RCBO, 5SU1324-6KX16, 2-pole, type A, 30 mA, B-curve, 16 A, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 110/120 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-6KX16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-6KX16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-6KX16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum75 °C
Minimum-40 °C
Width54 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1324-6KX16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-6KX16 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It protects a 16 A single-phase circuit against overload, short-circuit, and earth leakage, with a 30 mA type A residual-current trip that catches pulsating DC faults from electronics or variable-speed drives. Rated 10 kA breaking capacity per EN 60898, and 20 kA per IEC 60947-2 — the higher IEC figure matters when this RCBO sits in an industrial panel where the prospective fault current at the board exceeds 10 kA. Verify your line-to-neutral voltage before specifying.

Survives the nacelle — wide temperature and surge resilience

Rated for -40 °C to 75 °C ambient, this RCBO handles the thermal swing inside a turbine nacelle or outdoor enclosure without derating. The 4 kV surge voltage resistance and 1 kA surge current (8/20 µs) mean it takes lightning-induced transients on the line side — no up-tower swaps from a close strike.

Panel fit and compliance notes

IP20 rating applies once the distribution board is installed with connected conductors — the front face is finger-safe; the busbar area is not. Compliance documentation: the SENTRON series carries CE marking and is designed to EN 60898 and IEC 60947-2. RoHS and REACH declarations are standard with the product from Siemens. No UL listing is cited on this variant — verify for North American installations.

Frequently asked questions

What is 5SU1324-6KX16's listed width (54 mm) on this component line?

Width is 54 mm, which corresponds to 3 modular width units on standard DIN rail.

Will 5SU1324-6KX16 drop into a panel that was specified around 5SU9354-7KK16 without rewiring?

Not without rewiring. The 5SU9354-7KK16 is a 1P+N unit rated 230/240 V with C-curve, while this is a 2P unit at 110/120 V with B-curve. The 5SU1324-6KX16 is 54 mm wide (3 MW) versus 36 mm (2 MW) for the peer, so it takes an extra module slot. The voltage difference also means the neutral and phase wiring differ.

MPN