5SU1346-6FP10 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1346-6FP10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1346-6FP10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum70 °C
Minimum-40 °C
Width72 mm
Height85 mm
Depth72 mm
Installation depth70 mm
5SU1346-6FP10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1346-6FP10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

What this RCBO does on the line

The Siemens 5SU1346-6FP10 is a 4-pole RCBO from the SENTRON family, combining overcurrent and residual current protection in a single 72 mm-wide module. At 72 mm deep and 85 mm high, it fits standard DIN-rail enclosures; the 4 MW width (72 mm) occupies four 18 mm modular spaces.

Temperature derating and real-world current

In a warm panel at 40 °C, the continuous current drops to 9.6 A; at 50 °C it's 9.1 A; at 60 °C it's 8.6 A. If your enclosure runs hot — say 70 °C — the RCBO is limited to 8.2 A. That derating curve (–) is the one to check against the actual load current at the panel's internal ambient, not the room temperature.

The B-curve trips between 3 and 5 times rated current — so for a 10 A device, magnetic release starts at 30 A and is guaranteed by 50 A. That's standard for resistive and general-purpose loads; it coordinates downstream of a higher-rated SENTRON MCCB or NH fuse. Insulation voltage is 500 V, surge voltage resistance is 4 kV.

The 5SU1346-6FP10 is designed and tested to EN 60898 (6 kA breaking capacity) and IEC 60947-2 (also 6 kA). The SENTRON brand documentation package includes CE declaration of conformity, RoHS and REACH compliance statements, and the standard Siemens quality certificate. No halogen-free designation on this variant.

Frequently asked questions

Where can I buy 5SU1346-6FP10 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time.

What are the key ratings for 5SU1346-6FP10?

4-pole RCBO, 10 A rated current at 30 °C, B tripping characteristic, 6 kA breaking capacity per EN 60898 and IEC 60947-2. Dimensions are 72 mm wide (4 MW), 72 mm deep, 85 mm high.

Will 5SU1346-6FP10 drop into a panel specified for 5SY6332-7CC without rewiring?

The 5SU1346-6FP10 is a 4-pole RCBO (combined overcurrent + residual current) while the 5SY6332-7CC is a 3-pole MCB (overcurrent only). They are functionally different devices — the RCBO adds earth leakage protection. Panel fit may differ in width and wiring requirements; verify the specific terminal layout and neutral connection before substituting.

What compliance documentation does Siemens provide for 5SU1346-6FP10?

The SENTRON brand provides CE declaration of conformity, RoHS and REACH compliance statements, and standard quality certification. The part is tested to EN 60898 and IEC 60947-2. No halogen-free designation applies to this variant.