Siemens 5SU1346-6FP16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1346-6FP16 SENTRON RCBO, 4P, B-16A, 6kA

MPN5SU1346-6FP16
Active

Siemens SENTRON RCBO, 4-pole, B-curve, 16 A rated, 6 kA breaking capacity, 72 mm wide, instantaneous design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU1346-6FP16 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1346-6FP16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1346-6FP16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum70 °C
Minimum-40 °C
Width72 mm
Height85 mm
Depth72 mm
Installation depth70 mm
5SU1346-6FP16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1346-6FP16 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

Rated 16 A at 30 °C, it derates to 12.5 A at 70 °C — that thermal curve matters if this lands in a crowded, warm panel. The 72 mm width occupies 4 modular-width units on a DIN rail.

Where it goes — panel integration and environment

Supply can feed from either top or bottom — handy when you're retrofitting into an existing busbar arrangement and can't flip the board.

What the spec table doesn't tell you — the so-what on key ratings

The 6 kA breaking capacity is the same under both EN 60898 (the MCB standard) and IEC 60947-2 (the industrial circuit-breaker standard). That dual rating means it's tested to both installation and industrial coordination rules — not all RCBOs carry both. The insulation voltage Ui of 500 V and surge voltage resistance of 4 kV give headroom for 400 V AC networks with reasonable transient immunity. The 0.25 kA surge current withstand at 8/20 μs is the impulse rating for the residual-current electronics — it tells you the internal electronics can ride through a lightning-induced surge on the line side without latching or failing.

Frequently asked questions

How do I get current pricing and availability for 5SU1346-6FP16?

Pricing and availability are confirmed at quote time. Submit an RFQ through the storefront; the part is sourced through independent distribution and quoted to order.

What is the depth of 5SU1346-6FP16?

The depth is 72 mm, with an installation depth of 70 mm. The width is also 72 mm at 4 modular units.

What compliance documentation does this RCBO carry?

The 5SU1346-6FP16 is rated per EN 60898 and IEC 60947-2, with overvoltage category III and pollution degree 3. The evidence does not list RoHS, REACH, or UL marks specifically — verify with the manufacturer for full compliance declarations.

Will 5SU1346-6FP16 drop into a panel specified around 5SU9354-7KK16 without rewiring?

Both are 4-pole SENTRON RCBOs on a 72 mm (4 MW) DIN-rail footprint, so the mechanical fit and busbar pitch are the same. The 5SU1346-6FP16 is a B-curve 16 A unit; the 5SU9354-7KK16 is a different variant — verify the tripping curve and rating match your circuit before swapping. No wiring changes needed if the ratings align.