Siemens 5SU1346-7FP13 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU1346-7FP13 RCBO, 4P C13 30mA Type A, 6kA

MPN5SU1346-7FP13
Active

Siemens SENTRON 5SU1346-7FP13 RCBO, 4-pole, 13 A rated, C tripping characteristic, 30 mA Type A residual current, 6 kA breaking capacity per EN 60898, 4 MW width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU1346-7FP13 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU1346-7FP13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1346-7FP13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum70 °C
Minimum-40 °C
Width72 mm
Height85 mm
Depth72 mm
Installation depth70 mm
5SU1346-7FP13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1346-7FP13 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Siemens SENTRON 5SU1346-7FP13 — 4-pole RCBO, 13 A C-curve, 30 mA Type A

The 4 MW (72 mm) width and IP20 finger-safe terminals mean it snaps into a standard 4-module DIN-rail slot in a consumer unit or panelboard.

At 13 A rated current, the RCBO handles continuous loads up to that value; derate per the temperature table: 12.2 A at 40 °C, 11.7 A at 45 °C, 11.2 A at 50 °C, 10.8 A at 55 °C, and 10.3 A at 60 °C ambient. Type A residual current detection covers pulsating DC fault currents from rectified loads (SMPS, LED drivers, VFDs) in addition to sinusoidal AC — important for modern panels with electronic loads. The 4 kV rated surge voltage withstand confirms coordination with standard SPDs at the service entrance.

Supply can enter from either top or bottom, and mounting position is unrestricted — install it in any orientation within the distribution board. The IP20 protection rating applies when the board is installed with conductors connected; the enclosure itself provides the additional ingress protection for the panel environment. Depth is 72 mm, installation depth 70 mm, height 85 mm — fits standard 4-module cutouts in consumer units and panelboards.

Frequently asked questions

What is the breaking capacity of 5SU1346-7FP13?

It is rated 6 kA per both EN 60898 and IEC 60947-2, suitable for final circuits in residential and light commercial distribution boards.

What does Type A residual current mean on this RCBO?

Type A detects pulsating DC fault currents from rectified loads (SMPS, LED drivers, VFDs) in addition to sinusoidal AC, covering modern electronic loads in the circuit.

What is the temperature derating for 5SU1346-7FP13?

Rated 13 A at 30 °C, derated to 12.2 A at 40 °C, 11.7 A at 45 °C, 11.2 A at 50 °C, 10.8 A at 55 °C, and 10.3 A at 60 °C ambient.

Where can I buy 5SU1346-7FP13 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.