Siemens 5SU1353-7KK08 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1353-7KK08 SENTRON RCBO, 8A Type C, 30mA Type A,

MPN5SU1353-7KK08

Siemens SENTRON 5SU1 RCBO, 8 A rated current, Type C tripping characteristic, Type A fault current, 4.5 kA breaking capacity, 2-pole (1P+N), 36 mm width.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1353-7KK08 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1353-7KK08 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1353-7KK08 — Mechanical
ParameterValue
Mounting positionany
Maximum2.4 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1353-7KK08 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1353-7KK08 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What it is and what it does

The Siemens 5SU1353-7KK08 is a 2-pole (1P+N) RCBO from the SENTRON 5SU1 series, combining overcurrent protection and residual current detection in a single 36 mm-wide module. Rated 8 A with a Type C tripping characteristic and a Type A fault current sensitivity, it breaks fault currents up to 4.5 kA per EN 60898. That Type A rating means it catches pulsating DC fault currents — the kind rectified loads like switch-mode supplies and VFDs can produce — not just pure AC sine-wave faults. If your panel feeds electronics, this is the right residual-current class.

Ratings that matter for the panel

The 8 A rating is at 30 °C ambient. Above that, the continuous current derates: 7.52 A at 40 °C, 7.28 A at 45 °C, 6.96 A at 50 °C, 6.48 A at 55 °C, 6.48 A at 60 °C, 6.16 A at 65 °C, and 5.84 A at 70 °C. If your enclosure runs hot — say a packed panel with drives — size the load to the derated figure at your actual ambient, not the 30 °C headline. The RCBO itself is rated for ambient -25 to +55 °C operating, with storage from -40 to +75 °C. Conductor termination accepts solid or stranded wire from 0.75 mm² up to 35 mm², so it handles both the small control-circuit tails and the heavier power feeds. The 77 mm depth and 70 mm installation depth fit standard 36 mm-wide DIN-rail enclosures; mounting position is any orientation. Power supply can enter from top or bottom — no forced busbar routing.

Frequently asked questions

What are the key ratings of 5SU1353-7KK08?

Rated current 8 A, Type C trip curve, Type A fault current sensitivity, 4.5 kA breaking capacity per EN 60898, 2-pole 1P+N.

What is the depth of 5SU1353-7KK08?

The depth is 77 mm, with an installation depth of 70 mm.

What conductor sizes does 5SU1353-7KK08 accept?

Solid and stranded conductors from 0.75 mm² to 35 mm².