Siemens 5SU1353-7KL20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1353-7KL20 SENTRON RCBO, 2-pole 20A C-curve, Type

MPN5SU1353-7KL20

Siemens SENTRON RCBO, 2-pole, 20 A rated, C characteristic, Type A residual current, 4.5 kA per EN 60898, 2 MW, 77 x 36 x 90 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1353-7KL20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1353-7KL20 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SU1353-7KL20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1353-7KL20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1353-7KL20 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

RCBO for mixed-load final circuits

The Siemens 5SU1353-7KL20 is a 2-pole RCBO (residual-current circuit breaker with overcurrent protection) from the SENTRON family, rated 20 A with a C tripping characteristic and Type A residual-current sensitivity. The C curve (5–10× In magnetic trip) suits mixed loads with moderate inrush — lighting banks, small motorised valves, or socket circuits in commercial panels. Type A RCD detects pulsating DC fault currents, covering electronics-fed loads like switched-mode supplies and variable-speed drives, which a plain AC type would miss. Breaking capacity is 4.5 kA per EN 60898 and 5 kA per IEC 60947-2, sufficient for most final sub-distribution boards in residential or light commercial installations where the prospective fault current stays under those thresholds. Overvoltage category III and pollution degree 2 confirm it is rated for fixed-installation mains connection, not plug-in portable use.

Thermal derating — real-world current

The 20 A rating holds only at 30 °C ambient. At 40 °C it derates to 18.8 A; at 50 °C to 17.4 A; at 60 °C to 16.2 A; at 70 °C to 14.6 A. If the panel runs warm — typical inside a packed distribution board — size the upstream protective device and load accordingly. The full derating table runs from 30 °C through 70 °C in 5 °C steps.

Mounting and integration

Two modular-width units (36 mm) snap onto standard DIN rail. Depth is 77 mm, installation depth 70 mm — it clears most 80 mm-deep enclosures. Supply can enter from top or bottom, which simplifies busbar routing in retrofit panels. Touch protection is built in, IP20 when the distribution board is closed. Halogen-free and silicon-free construction matters in environments sensitive to outgassing — clean rooms, medical facilities, or areas with silver contacts that corrode under silicone vapour.

Frequently asked questions

What is the depth of 5SU1353-7KL20?

Depth is 77 mm; installation depth (behind the panel face) is 70 mm.

What is the width of 5SU1353-7KL20?

Width is 36 mm, which is 2 modular-width units on standard DIN rail.

Will 5SU1353-7KL20 drop into a panel specified around 5SL6550-7BB without rewiring?

Both are 2-pole RCBOs on a 36 mm footprint, so the mechanical fit is the same. However, 5SL6550-7BB is a 50 A B-curve device with different breaking capacity and RCD type — verify the load current and selectivity before swapping.

Where can I buy 5SU1353-7KL20?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.