Siemens 5SU1354-0KK06 SENTRON RCBO, 6A, B-Curve, 30mA, 10kA

MPN5SU1354-0KK06

Siemens SENTRON RCBO, 1P+N, 6 A, B-curve, 30 mA Type AC, 10 kA (EN 60898), 35 kA (IEC 60947-2), 2 MW, 230/240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-0KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-0KK06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1354-0KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-0KK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-0KK06 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It protects a 1P+N final subcircuit at 6 A rated current, B-curve tripping characteristic, with 30 mA Type AC residual-current protection. That dual standard means it coordinates downstream of a larger upstream breaker without needing a current-limiting device in between.

Mounts in any position. Rated IP20 once the distribution board is closed and conductors are connected; that's standard for a DIN-rail device inside a cabinet, not for an open panel. Halogen-free and silicon-free construction, which matters in clean-room or high-reliability environments where outgassing is a concern.

Frequently asked questions

What is the breaking capacity of 5SU1354-0KK06?

10 kA per EN 60898 and 35 kA per IEC 60947-2. The higher figure under the industrial standard gives additional fault-current headroom for coordination studies.

Will 5SU1354-0KK06 drop into a panel that was specified around 5SU9354-7KK16 without rewiring?

The 5SU9354-7KK16 is a C-curve variant with the same 2 MW footprint, 36 mm width, 77 mm depth, and 230/240 V AC rating. It will physically fit the same DIN-rail position and busbar arrangement. The functional difference is the tripping characteristic — B-curve (3-5× In) on the 5SU1354-0KK06 versus C-curve (5-10× In) on the peer — so check that the load's inrush profile matches the curve before swapping.

Where can I buy 5SU1354-0KK06?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm commercial response.

MPN