Skip to main content
Siemens 5SU1354-0KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-0KK10 SENTRON RCBO, 10 A, Type B, 10 kA

MPN5SU1354-0KK10

Siemens SENTRON 5SU1354-0KK10 RCBO, 1P+N, Type B, 10 A at 30 °C, 10 kA (EN 60898), 20 kA (IEC 60947-2), 2 MW, IP20.

$35.56Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-0KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-0KK10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1354-0KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-0KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-0KK10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

Siemens 5SU1354-0KK10 — SENTRON RCBO, Type B, 10 A

The breaking capacity is rated 10 kA according to EN 60898 and 20 kA according to IEC 60947-2, giving the buyer flexibility depending on the applicable standard at the installation site. The higher IEC rating covers industrial panel applications where prospective fault currents may exceed the domestic standard's limit. Operating frequency is fixed at 50 Hz; the unit is designed for 230/240 V AC supply.

Thermal derating and installation constraints

The 5SU1354-0KK10 carries a published derating curve: 10 A at 30 °C ambient, stepping down to 9.5 A at 40 °C, 9.3 A at 45 °C, 9 A at 50 °C, 8.7 A at 55 °C, 8.5 A at 60 °C, 8.2 A at 65 °C, and 8 A at 70 °C. In a crowded DIN-rail enclosure with multiple RCBOs side-by-side, the effective rating at typical 40–50 °C internal ambient is what governs the circuit design — not the 30 °C nameplate number. The IP20 rating applies once the distribution board is installed with connected conductors — the device itself is not rated for exposed or wet locations. Supply connection can be made from either the top or bottom, and the unit is halogen-free and silicon-free — relevant for environments with strict material restrictions (e.g., rail, marine, or cleanroom adjacent panels).

Frequently asked questions

What are the key ratings of 5SU1354-0KK10?

It is a 1P+N RCBO rated 10 A at 30 °C with Type B tripping characteristic, 10 kA breaking capacity per EN 60898, and 20 kA per IEC 60947-2. Operating voltage is 230/240 V AC at 50 Hz.

Where can I buy 5SU1354-0KK10 and how is it quoted?

This part is sourced through independent industrial distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What compliance documentation does 5SU1354-0KK10 carry?

The device is designed to EN 60898 and IEC 60947-2, with an insulation voltage of 264 V, surge voltage resistance of 4 000 V, overvoltage category III, and pollution degree 2. It is halogen-free and silicon-free.

MPN
5SU1354-0KK10