Siemens 5SU1354-0KK16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-0KK16 SENTRON RCBO, 16A, 10kA, Type B, 1P+N

MPN5SU1354-0KK16

Siemens SENTRON 5SU1354-0KK16 RCBO, 16 A at 30 °C, Type B, 10 kA (EN 60898), 1P+N, 2 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-0KK16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-0KK16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1354-0KK16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-0KK16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-0KK16 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

RCBO for final-circuit protection

Type B tripping characteristic (3–5× In magnetic release) suits residential and light commercial final circuits where inrush from lighting or small electronics is moderate — not motor or transformer loads that need Type C or D. Current rating is temperature-dependent: 16 A at 30 °C, derated to 15.2 A at 40 °C, 14.4 A at 50 °C, and 12.32 A at 70 °C. In a warm enclosure (40–50 °C typical for a loaded panel), expect to apply the 40 °C or 50 °C column for continuous load sizing — not the 30 °C headline figure. The 1P+N design switches the line conductor only; the neutral is switched internally for isolation but not protected against overcurrent. That matches single-phase final circuits where the neutral is not overloaded. Mounting position any, supply feed from top or bottom — flexible for panel layout.

Frequently asked questions

Where can I buy 5SU1354-0KK16 and how do I get a price?

This RCBO is sourced to order against an RFQ through independent distribution. Submit a request for a firm quote; availability and current pricing are confirmed at that time.

What is the breaking capacity of 5SU1354-0KK16?

Rated 10 kA per EN 60898 and 20 kA per IEC 60947-2 — the higher figure applies when the device is used in industrial coordination studies under the product standard for circuit-breakers.

Does 5SU1354-0KK16 drop into a panel built for 5SY4116-6CC?

Both are 2-module-wide (36 mm) DIN-rail devices, so the footprint matches. However, 5SU1354-0KK16 is a combined RCBO (MCB+RCD) while 5SY4116-6CC is a standalone MCB — the RCBO adds residual-current protection and requires a neutral connection. Rewiring is needed if the panel originally had a separate RCCB upstream.

What compliance documentation does Siemens provide for 5SU1354-0KK16?

The device is halogen-free and silicon-free, rated IP20 in an installed distribution board. It is designed to EN 60898 and IEC 60947-2. Standard Siemens declarations (CE, UKCA) apply; specific RoHS/REACH statements are available on request.