Skip to main content
Siemens 5SU1354-1KK06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-1KK06 SENTRON RCBO, 6A C-curve 10kA, 1P+N

MPN5SU1354-1KK06

Siemens SENTRON 5SU1354-1KK06 RCBO, 1P+N, rated current 6 A at 30 °C, tripping characteristic C, breaking capacity 10 kA per EN 60898 / 35 kA per IEC 60947-2, 2 modular width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-1KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-1KK06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1354-1KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-1KK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-1KK06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU1354-1KK06 is a SENTRON RCBO — a combined residual-current circuit breaker with overcurrent protection in a single 2-module-width package (36 mm wide, 77 mm deep, 90 mm tall). It protects a single-phase final subcircuit: one pole switched and protected, neutral switched but not protected (1P+N design).

That 35 kA figure gives real SCCR headroom downstream of a larger upstream breaker — useful when coordinating with a 63 A or 100 A feeder in a Type 2 coordination study.

Temperature derating — don't ignore it

At 40 °C it derates to 5.7 A, at 50 °C to 5.4 A, at 60 °C to 5.1 A, and at 70 °C to 4.62 A. If this RCBO lives in a crowded DIN rail enclosure near transformers or drives, size the load to the derated current at the expected internal temperature — not the 30 °C nameplate figure.

Mounts in any position on DIN rail. IP20 with conductors connected and board installed.

Frequently asked questions

Where can I buy 5SU1354-1KK06 and how do I get a price?

Sourced to order against an RFQ through independent distribution channels. Submit a request for quote; availability and current pricing are confirmed at quote time.

Will 5SU1354-1KK06 drop into a panel specified around 5SL6550-7BB without rewiring?

Both are 2-module-width (36 mm) SENTRON RCBOs on the same DIN rail footprint, so mechanical fit is identical. However, the C-curve vs B-curve difference means the trip threshold changes — verify selectivity with the upstream breaker before swapping.

What compliance documentation does Siemens provide for 5SU1354-1KK06?

The part carries EN 60898 and IEC 60947-2 ratings, is halogen-free and silicon-free, and is designed for overvoltage category III and pollution degree 2. Standard Siemens declarations (CE, UKCA) apply per the SENTRON series documentation.

MPN
5SU1354-1KK06