Siemens 5SU1354-1LB13 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-1LB13 RCBO, 13 A, C-curve, 10 kA, 2-pole

MPN5SU1354-1LB13

Siemens SENTRON 5SU1354-1LB13, RCBO, 13 A, C-curve, 10 kA per EN 60898, 2-pole 1P+N, 2 width units, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU1354-1LB13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU1354-1LB13 — Identification
ParameterValue
Product designationRCBO

Mechanical

5SU1354-1LB13 — Mechanical
ParameterValue
Mounting positionany
Maximum4.4 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU1354-1LB13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU1354-1LB13 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What this RCBO delivers on the panel rail

The Siemens SENTRON 5SU1354-1LB13 is a 2-pole (1P+N) RCBO rated at 13 A with a C tripping characteristic, meaning it handles moderate inrush from motor starters or lighting ballasts without nuisance tripping, while still clearing overloads within the standard thermal-magnetic curve. Its 10 kA breaking capacity per EN 60898 covers most commercial and light industrial distribution boards fed from a transformer of typical impedance. The unit occupies 2 width units (36 mm) on a DIN rail, with an installation depth of 70 mm and overall depth of 77 mm — fits standard 80 mm deep enclosures. Rated current derates with ambient temperature: 13 A at 30 °C, 12.48 A at 40 °C, 11.96 A at 50 °C, 10.53 A at 65 °C, and 10.01 A at 70 °C. For a panel running at 45 °C ambient, expect 12.22 A continuous — enough margin for a 10 A resistive load or a 1.5 kW motor circuit. The RCBO is halogen-free and silicon-free, which matters for clean-room or semiconductor-adjacent installs where outgassing contaminates optics or wafers.

Terminal capacity and wiring flexibility

Both solid and stranded conductors from 0.75 mm² up to 35 mm² are accepted. The supply cord can enter from either top or bottom. Overvoltage category III means it's rated for fixed installation downstream of the main distribution board.

Coordination and selectivity notes

Energy limiting class 3 aids downstream coordination with smaller MCBs. The type of fault current is AC, so it's not suitable for pulsating DC or smooth DC fault currents. The test circuit requires a minimum of 195 V to operate the test button.

Frequently asked questions

What is 5SU1354-1LB13's listed depth?

Overall depth is 77 mm; installation depth (behind the panel face) is 70 mm.

What conductor sizes does 5SU1354-1LB13 accept?

Both solid and stranded conductors from 0.75 mm² up to 35 mm².