Siemens 5SU1354-1LB32 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-1LB32 SENTRON RCBO, 32 A, 10 kA, Type C

MPN5SU1354-1LB32

Siemens SENTRON 5SU1354-1LB32 RCBO, 2-pole 1P+N, 32 A rated current, 10 kA breaking capacity, Type C tripping characteristic, AC fault current type.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-1LB32 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-1LB32 — Identification
ParameterValue
Product designationRCBO
5SU1354-1LB32 — Mechanical
ParameterValue
Mounting positionany
Maximum11.4 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1354-1LB32 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-1LB32 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Rated 32 A at 230/400 V AC with a 10 kA breaking capacity per EN 60898, it covers the common residential and light-commercial branch circuit where both earth leakage and overload/short-circuit protection are needed in one DIN-rail device. The Type C tripping characteristic (5–10× In magnetic release) suits motor and lighting loads with moderate inrush; the AC fault-current type detects sinusoidal residual currents. Active in the current Siemens lineup, so factory supply is standard — no last-time-buy pressure.

Wire capacity: solid or stranded 0.75–35 mm² — that's a generous terminal for a 32 A device, allowing easy feed-through of larger supply conductors. Mounting position any, which simplifies panel layout.

Rated current drops with ambient temperature: 32 A at 30 °C, 30.4 A at 40 °C, 28.8 A at 50 °C, down to 24.64 A at 70 °C. If the panel runs hot (e.g., enclosed switchgear or adjacent heat sources), use the 50 °C or 60 °C column for your load calculation. Operating ambient range -25 to +55 °C; storage -40 to +75 °C. Maximum power dissipation 11.4 W — relevant for thermal budgeting in a multi-device enclosure.

The 5SU1 design is the standard Siemens RCBO platform for the European and export markets.

Frequently asked questions

What wire sizes does 5SU1354-1LB32 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm² — the terminals handle both fine-stranded and solid copper.

What is the difference between 5SU1354-1LB32 and 5SL6563-7BB?

5SL6563-7BB is a Siemens MCB (no residual-current function), while 5SU1354-1LB32 is an RCBO combining overcurrent and earth-leakage protection in one unit. They are not direct drop-in replacements — the RCBO requires the neutral connection and has a different wiring scheme.

MPN
5SU1354-1LB32