Skip to main content
Siemens 5SU1354-1RC06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU1354-1RC06 SENTRON RCBO, 6A, C-curve, 30mA, 2-pol

MPN5SU1354-1RC06

Siemens SENTRON RCBO, 5SU1354-1RC06, 6 A rated, C characteristic, 30 mA residual current, 2-pole (1P+N), 2 MW, Type AC, 10 kA / 35 kA breaking capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1354-1RC06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1354-1RC06 — Identification
ParameterValue
Product designationRCBO
5SU1354-1RC06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SU1354-1RC06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1354-1RC06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SU1354-1RC06 is a 2-pole (1P+N) RCBO rated at 6 A with a C tripping characteristic and 30 mA Type AC residual current protection. The C curve handles moderate inrush from motorized or capacitive loads without nuisance tripping, while the 30 mA residual element covers personnel protection in final circuits.

The 35 kA figure under IEC 60947-2 means this RCBO can interrupt high prospective fault currents typical in industrial panelboards — useful where the upstream transformer is close. The 10 kA EN 60898 rating covers the residential and commercial installation standard.

Environmental range and mounting

Depth is 70 mm, height 90 mm, width 36 mm (2 MW).

Frequently asked questions

What is the breaking capacity of 5SU1354-1RC06?

10 kA per EN 60898 and 35 kA per IEC 60947-2. The higher 35 kA figure applies under the industrial standard, giving headroom for high-fault installations.

Will 5SU1354-1RC06 drop into a panel specified around 5SU9354-7KK16?

The 5SU9354-7KK16 is a different variant — same 2 MW width (36 mm) and 70 mm installation depth, but its breaking capacity under IEC 60947-2 is 10 kA versus 35 kA on this unit. Both share the same DIN-rail footprint, so mechanical fit is identical; the electrical rating difference matters for fault-current coordination.

What compliance documentation does Siemens provide for 5SU1354-1RC06?

The part carries ratings per EN 60898 and IEC 60947-2, which implies CE marking for the European market. Standard Siemens documentation includes a declaration of conformity; RoHS and REACH compliance data is available through the manufacturer's product support channels.

How do I get current pricing and availability for 5SU1354-1RC06?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time — we source through independent distribution channels.

MPN
5SU1354-1RC06